MOUNT AIRY, MD —
OSHA Inspection: U.S. POSTAL SERVICE - MT. AIRY MD
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of U.S. POSTAL SERVICE - MT. AIRY MD in 505 WINDY KNOLL DR., MOUNT AIRY, MD 21771 (NAICS 491110). OSHA activity number 341304962.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. POSTAL SERVICE - MT. AIRY MD
- Site address
- 505 WINDY KNOLL DR.
- City
- MOUNT AIRY
- State
- MD
- ZIP
- 21771
- Mailing
- 505 WINDY KNOLL DR., MOUNT AIRY, MD 21771
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 491110
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.305 G01 IV A
- Issued
- Aug 4, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $392 · Current $392
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): A flexible cord was used as a substitute for the fixed wiring of a structure: a) Main Floor - On or about 02/22/2016, a 14 gauge orange cord set was used in lieu of permanent wiring to power a postal scanning machine. The U.S. Postal Service was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 1106243, citation number 1, item number 1 and was affirmed as a final order on 12/21/2015, with respect to a workplace located at 1300 Evans Ave., San Francisco, California 94188. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — I $8200
- — Z $11760
- — Z (R) $392
1910.305 G01 IV D
- Issued
- Aug 4, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces: a) Main Floor On or about 02/22/2016, a 14 gauge cord set, used to provide power to a postal scanning machine, was attached to an enclosure by means of wire ties. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (3)
- — I $20800
- — Z $30000
- — Z (O) $0
More inspections at U.S. Postal Service - MT. Airy MD
View U.S. Postal Service - MT. Airy MD's full OSHA safety record →
More inspections in this industry (NAICS 491110)
More inspections in MD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341304962.