OSHA Inspection: COLLINGWOOD CONSTRUCTION CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLLINGWOOD CONSTRUCTION CORP. in 8172 WOODVIEW COURT, WILLIAMSVILLE, NY 14221 (NAICS 238160). OSHA activity number 341311900.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Collingwood Construction Corp. — free Get an email when a new federal OSHA severe-injury report for Collingwood Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
8172 WOODVIEW COURT
City
WILLIAMSVILLE
State
NY
ZIP
14221
Mailing
2670 MILLERSPORT HIGHWAY, GETZVILLE, NY 14068
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 22, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:   a) On or about 3/8/16, at the roof area of the site, Williamsville, NY. Employees, on a ladder jack scaffold performing tear-off of the roof, were not protected by fall protection(s).   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1926.501 B11

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 22, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:   a) On or about 3/8/16, at the roof area of the site, Williamsville, NY. Employees, on a 8 in 12 steep roof performing tear-off, were not protected by fall protection system(s).   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

View Collingwood Construction Corp.'s full OSHA safety record →