Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TROY, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TROY, LLC in 625 NORTH PENN AVE, HARRISVILLE, WV 26362 (NAICS 313230). OSHA activity number 341325397.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Troy, LLC — free Get an email when a new federal OSHA severe-injury report for Troy, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TROY, LLC
Site address
625 NORTH PENN AVE
City
HARRISVILLE
State
WV
ZIP
26362
Mailing
625 NORTH PENN AVE, HARRISVILLE, WV 26362
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313230
Employees
67
Ownership type
A

7 citations on file for this inspection.

1910.146 C04

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 8, 2016
Abate by
Jul 14, 2016
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:      (a) Dalton Oven: On or about February 29, 2016, and times prior, employees are required to enter a Dalton Oven to un-jam or clean it. The oven has 480 three phase electrical and natural gas line energy sources. The employer did not implement a written permit space entry program in accordance with 29 CFR 1910.146.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.146 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 8, 2016
Abate by
Jul 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit:    (a) Dalton Oven: On or about February 29, 2016, and times prior, employees are required to enter a Dalton Oven to un-jam or clean it. The oven has 480 three phase electrical and natural gas line energy sources. The employer did not document the completion of measures by utilizing an entry permit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 H

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 8, 2016
Abate by
Jul 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(h): The employer did not ensure that all authorized entrants were trained to perform the duties required by (h)(1)-(5) of this section (29 CFR 1910.146):    (a) Dalton Oven: On or about February 29, 2016, and times prior, employees are required to enter a Dalton Oven to un-jam or clean it. The oven has 480 three phase electrical and natural gas line energy sources. The employer did not train the authorized entrants on the duties required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 8, 2016
Abate by
Jul 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(i)(1): The employer did not ensure that each attendant knew the hazards that could be faced during entry, including information on the mode, signs or symptoms, and consequences of the exposure:    (a) Dalton Oven: On or about February 29, 2016, and times prior, employees are required to enter a Dalton Oven to un-jam or clean it. The oven has 480 three phase electrical and natural gas line energy sources. The employer did not train the authorized attendants on the hazards during entry.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 8, 2016
Abate by
Aug 18, 2016
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) H5 Folder: On or about February 29, 2016, and times prior, employees feed trim through a lag roll on the H5 Folder. The employer did not provide one or more methods of machine guarding to protect the employee from the rotating parts.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1904.32 A02

Other-than-serious 1 instance 1 exposed
Issued
Jul 8, 2016
Penalty
Initial $700 · Current $420 Reduced
29 CFR 1904.32(a)(2): The employer did not create an annual summary of injuries and illnesses recorded on the OSHA 300 Log.       (a) Troy, LLC.: On or about March 14, 2016, and times prior, the 2015 OSHA form 300A, or equivalent, Summary of Work Related Injuries and Illness was not created.
Recent events (2)
  • — I (O) $420
  • — Z (O) $700

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Jul 8, 2016
Abate by
Jul 14, 2016
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours.      (a) Troy, LLC: An in-patient hospitalization of an employee injured in a work-related incident was not reported within 24 hours. The in-penitent hospitalization occurred on February 29, 2016 and OSHA was not made aware of the injury until March 7, 2016.
Recent events (2)
  • — I (O) $2100
  • — Z (O) $3500

View Troy, LLC's full OSHA safety record →