GAINESVILLE, GA —
OSHA Inspection: U.S. PIPE FABRICATION, LLC
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of U.S. PIPE FABRICATION, LLC in 1101 INDUSTRIAL BOULEVARD, GAINESVILLE, GA 30504 (NAICS 332996). OSHA activity number 341328946.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. PIPE FABRICATION, LLC
- Site address
- 1101 INDUSTRIAL BOULEVARD
- City
- GAINESVILLE
- State
- GA
- ZIP
- 30504
- Mailing
- 1101 INDUSTRIAL BOULEVARD, GAINESVILLE, GA 30504
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 23
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 F03 II D
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $4,950 · Current $3,218 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment. On 3/7/16, at the Gainesville, Georgia facility, the employer did not have each authorized employee performing service and maintenance to equipment affix their own lockout lock to the equipment on which work was being performed. i.e. Authorized employees with locks were locking out for other employees who were not provided locks by the employer (and had not been trained as designated Authorized employees).
Recent events (2)
- — I (S) $3218
- — Z (S) $4950
1910.157 G01
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $3,960 · Current $2,574 Reduced
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting. On 3/15/16, at the Gainesville facility, the employer did not instruct employees in hazards involved with incipient stage fire fighting and/or did not implement an Emergency Action Plan in lieu of that training.
Recent events (2)
- — I (S) $2574
- — Z (S) $3960
1910.212 A03 II
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $4,950 · Current $3,218 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). On 3/15/16, at the Gainesville facility in the saw area, the employer did not ensure the job made saws were guarded so as to prevent employee exposure to cuts and amputations.
Recent events (2)
- — I (S) $3218
- — Z (S) $4950
1910.147 C04 II B
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $34,650 · Current $22,523 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On 3/15/16, at the Gainesville facility, the employer did not ensure specific written Lockout procedures implemented at the facility addressed all hazards and requirements. Deficiencies included: 1 Disconnect locations 2 Identification of all energies and magnitudes of energies 3 No lock removal procedure 4 Address all equipment serviced and maintained on site Custom Fab, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(4)(ii)(b), which was contained in OSHA inspection number 978943, citation number 1, item number 2 and was affirmed as a final order on 6/20/2014, with respect to a workplace located at 109 5th St., Orlando, Florida. Custom Fab, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(4)(ii)(b), which was contained in OSHA inspection number 1064509, citation number 2, item number 1 and was affirmed as a final order on 2/18/2016, with respect to a workplace located at 1101 Industrial Blvd., Gainesville, Georgia.
Recent events (2)
- — I (R) $22523
- — Z (R) $34650
1910.147 C07 I A
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $13,860 · Current $9,009 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. On 3/16/16, at the Gainesville facility, employees were performing Authorized work in that they were changing saw blades but were not trained as Authorized employees and were not using locks and protected by lockout measures when performing this work. U.S. Pipeline Fabrication, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(7)(i)(A), which was contained in OSHA inspection number 1064509, citation number 1, item number 2 and was affirmed as a final order on 2/18/2016, with respect to a workplace located at 1101 Industrial Blvd, Gainesville, Georgia.
Recent events (2)
- — I (R) $9009
- — Z (R) $13860
1910.212 A01
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $9,900 · Current $6,434 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points, rotating parts, flying chips and sparks. On 3/15/16, at the Gainesville facility in the production area, employees are exposed to finger and hand amputations as moving parts, spinning and rotating equipment used at the facility is not guarded. Instances include: a - Pipe Threader #2 b - Pipe Threader #4 c - Lathe #3 d - Lathe #4 e - Lathe #5 The U.S. Pipe and Fabrication (formerly Custom Fab, Inc.) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1064509, citation number 1, item number 3 and was affirmed as a final order on 2/18/2016, with respect to a workplace located at 1101 Industrial Blvd, Gainesville, Ga 30504.
Recent events (4)
- — I $5000
- — Z $5000
- — I (R) $6434
More inspections at U.S. Pipe Fabrication, LLC
View U.S. Pipe Fabrication, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341328946.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.