Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INDUCTION IRON

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INDUCTION IRON in 3710 HENDRICKS ROAD, AUSTINTOWN, OH 44515 (NAICS 332312). OSHA activity number 341329423.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Induction Iron — free Get an email when a new federal OSHA severe-injury report for Induction Iron is published. One employer, no account, unsubscribe in one click.
Establishment
INDUCTION IRON
Site address
3710 HENDRICKS ROAD
City
AUSTINTOWN
State
OH
ZIP
44515
Mailing
3710 HENDRICKS ROAD, AUSTINTOWN, OH 44515
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
10
Ownership type
A

16 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Aug 2, 2016
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    On or about March 16, 2016, the employer failed to ensure that the open sided platform located in building 11 of the facility was guarded with standard railings. The platform divides the facility into two sections and is identifiable as a former loading dock. Half of the platform length contained no guardrails.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.23 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Aug 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(1): A standard railing did not consist of a top rail, intermediate rail, and post, and did not have a vertical height of 42 inches nominal from upper surface of top rail to floor.  The intermediate rail was not half way between the top rail and the floor, platform, runway, or ramp.  On or about March 16, 2016, the employer failed to ensure that the open sided platform located in building 11 of the facility contained an intermediate rail. The platform divides the facility and is identified as a former loading dock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A01

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.37(a)(1): Exit routes shall not have flammable, explosive, combustible gases or flammable furnishings stored in the exit route.    a) On or about March 16, 2016 the employer failed to ensure that flammables were not stored near the exit route/ door. A flammable propane tank and plastic gasoline tank were stored next to the main exit door of building 11 at the facility.    b) On or about March 16, 2016 the employer failed to ensure that flammables were not stored near the exit route/ door. Diesel tanks were stored directly outside the north emergency exit door.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.37 A03

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    On or about March 16, 2016 the employer failed to ensure that exit routes leading to and directly in front of exit doors were clear and unobstructed. The exit door directly north of the main entrance contained material placed on the floor in front of it.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.106 B02 VII A

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Aug 2, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.106(b)(2)(vii)(a): Area(s) surrounding tank(s) containing flammable liquids were not provided with adequate drainage or dikes:    On or about March 16, 2016, the employer failed to ensure that the outdoor storage tanks of diesel fuel were provided with adequate drainage or dikes. Diesel fuel could be seen saturating the ground below the tanks.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.147 C01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On or about March 16, 2016 the employer failed to have in place a program for the control of hazardous energies. Employees at the facility perform servicing and maintenance on equipment including but not limited to air compressors, blasters, shears, and presses. Hazardous energies present on the equipment include pneumatic, hydraulic, electrical, and gravitational. Employees were observed maintaining equipment such as presses and blasters at the time of inspection.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1910.147 C07 I A

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    On or about March 16, 2016, the employer failed to provide authorized training for employees tasked with servicing and maintaining equipment in the facility. Employees at the facility perform servicing and maintenance on equipment including but not limited to air compressors, blasters, shears, and presses. Hazardous energies present on the equipment include pneumatic, hydraulic, electrical, and gravitational.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I B

Serious Gravity 10 1 instance 5 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:      On or about March 16, 2016, the employer failed to ensure that employees working in the facility where servicing and maintenance of equipment was taking place had received affected training of LO/TO. Employees at the facility perform servicing and maintenance on equipment including but not limited to air compressors, blasters, shears, and presses. Hazardous energies present on the equipment include pneumatic, hydraulic, electrical, and gravitational.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J01 II B

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Aug 2, 2016
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.179(j)(1)(ii)(b): 29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:     On or about March 16, 2016, the employer failed to perform periodic inspections for the overhead crane in use at the facility. An annual inspection had never been performed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1910.184 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Aug 2, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:    On or about March 16, 2016, the employer failed to ensure that alloy steel chains in use with the over head crane for lifting contained durable identification. The chains provided did not contain a tag with required information.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about the week of March 9, 2016, the employer failed to ensure that machine guarding was in place on the 1750 ton Billet shear. The exit side of the press did not contain guarding to protect the employees from the downward motion of the ram or press. Employees removed material from the exit side and can reach the hazardous area.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1910.219 E01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):    On or about the week of March 9, 2016, the employer failed to ensure that the belt and pulley of the compressor supplying power to the billet shear was effectively guarded. The guard did not completely cover the hazardous area on all sides exposing the employees in the area.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 B02 I

Serious Gravity 5 3 instances 8 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $2,400 · Current $1,000 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a) On or about March 16, 2016, the employer failed to ensure that the electrical panel box located above the feed table disconnect was covered. A cover was not in place exposing employees to electrical hazards.    b) On or about March 16, 2016, the employer failed to ensure the electrical panel box providing power to the air compressor of the billet shear was covered. Employees were exposed to exposed electrical wiring of 400v.     c) On or about March 16, 2016, the employer failed to ensure that electrical panels and conduit providing power to components of the billet shear were covered. Employees were exposed to electrical hazards of 120 and 220v as a result.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2400

1910.305 G02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    On or about March 16, 2016, the employer failed to ensure that flexible electrical cords being used in the facility were used in continuous lengths without splice. A flexible cord was being used for electrical hand tools in the main area of the facility and contained two spliced areas.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.1200 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $2,400 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On or about March 16, 2016, the employer failed to develop and have in place a hazard communication program. Employees are required to use and are exposed to hazardous chemicals including but not limited to antifreeze, lubricating oils, diesel fuel, oils, solvents, oxygen, and acetylene.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2400

1910.1200 H01

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 13, 2016
Abate by
Oct 3, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about March 16, 2016, employees were not trained in the safe handling and use of hazardous chemicals in the workplace. Employees use and are exposed to solvents, oils, antifreeze, diesel fuels, oxygen, and acetylene.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Induction Iron's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341329423.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.