OSHA Inspection: HP PELZER AUTOMOTIVE SYSTEMS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HP PELZER AUTOMOTIVE SYSTEMS, INC. in 1884 WARRENTON HWY, THOMSON, GA 30824 (NAICS 336399). OSHA activity number 341330702.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HP Pelzer Automotive Systems, INC. for free Get an email when a new federal OSHA severe-injury report for HP Pelzer Automotive Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1884 WARRENTON HWY
City
THOMSON
State
GA
ZIP
30824
Mailing
PO BOX 1145, THOMSON, GA 30824
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
423
Ownership type
Private (A)

21 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 7, 2016
Abate by
Nov 11, 2016
Penalty
Initial $12,471 · Current $7,100 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):  a) Plant, Airlay - On or about 03/08/16 and at times prior thereto employees climbed on top of the Bale Breakers in order to clean the machinery with compressed air. No fall protection equipment was in use to prevent falls from a 10 ft. elevation onto the concrete floor.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $7100
  • · Z (S) $12471

1910.147 F03 I

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $12,471 · Current $7,100 Reduced
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, department or other group:  a) Plant, Airlay Building -  On or about 03/08/16 and at times prior thereto employees  were assigned to clean the airlay equipment while only one person locked a main panel in the control room. Workers were not protected from  the sudden start of machinery and potential errors during shift changes.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $7100
  • · Z (S) $12471

1910.147 C05 I

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:  a) Plant, Airlay Building -  On or about 03/08/16 and at times prior thereto employees  were assigned to clean the airlay equipment and were not provided padlocks and/or other locking hardware to protect themselves from the sudden start of machinery.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $7,839 · Current $4,400 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) Plant, Mechanical Shop - On or about 03/08/16 and at times prior thereto the grey bench grinder did not have a work rest installed. The wheel guard was used in lieu of the work rest, with a 1.5 in. gap between the guard and the wheel.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $4400
  • · Z (S) $7839

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) Plant, Mechanical Shop - On 03/08/16 and at times prior thereto employees operated the grey bench wheel grinder with a 5/8 in. gap between the tongue guard and the wheel.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $7,839 · Current $4,400 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a) Plant, Low Weight Foam Molding - On or about 03/08/16 and at times prior thereto the 480 V Regal Advantage HE Series oil heater/circulator connected to Press #18 had a damaged strain relief device in the power cable. The outer jacket was withdrawn and the internal conductors and terminals were not protected.  b) Hot Mold Area -  On or about 03/08/16 and at times prior thereto the 480 V Regal Advantage HE Series oil heater/circulator connected to Press #2 had a damaged strain relief device in the power cable. The outer jacket was withdrawn and the internal conductors and terminals were not protected.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $4400
  • · Z (S) $7839

1910.332 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $9,799 · Current $5,500 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  a) Throughout the plant - Maintenance employees  were instructed to perform repairs in 480 V electrical equipment and the employer did not provide training in the recognition of general electrical hazards and arc-flash hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $5500
  • · Z (S) $9799

1910.333 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $12,471 · Current $7,100 Reduced
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were no deenergized before the employee worked on or near them:  a) Airlay - On or about 03/08/16 and at times prior thereto maintenance employees were instructed to repair the 480 V electrical panels for the Laroche machine. The work was performed with the panel doors open, in close proximity of live parts. The equipment was not de-energized.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $7100
  • · Z (S) $12471

1910.335 A01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  a) Throughout the plant - On or about 03/08/16 and at times prior thereto maintenance employees were instructed to conduct repairs of high voltage electrical equipment and the employer did not provide electrical protective equipment. Employees were exposed to arc flash hazards and accidental contact with live parts.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

5(a)(1)

Repeat Gravity 5 3 instances 4 exposed
Issued
Sep 7, 2016
Abate by
Nov 11, 2016
Penalty
Initial $48,994 · Current $27,900 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to thermal skin hazards:  a) Plant, Light Weight Foam Molding - On or about 03/08/16 the hot oil fittings in the back of presses #5 and #6 and in the two connected hot oil heaters/circulators were not insulated, exposing workers to accidental contact with the hot surfaces. (Nominal temperature: 450 F)   b) Plant, Hot Mold Area - On or about 03/08/16 and at times prior thereto the fittings in the dual portable heater connected to Press #16 were not insulated, exposing workers to accidental contact with the hot surfaces (Nominal temperature: 450 F).  c) Plant, Light Weight Foam Molding - On or about 03/08/16 and at times prior thereto the door of the portable oil heater/circulator attached to press #10 was broken and did not close, exposing workers to accidental contact with the hot surfaces (Nominal temperature: 450 F).  HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard, OSH Act of 1970 Section 5(a)(1), which was contained in OSHA inspection number 924666, citation number 1, item number 1, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $27900
  • · Z (R) $48994

1910.22 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $39,193 · Current $21,300 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.  a) Plant, Hot mold area - On or about 03/08/16 and at times prior thereto the concrete floor in the aisle leading to the Airlay was damaged, presenting level changes in excess of 1.5 in. (worker and forklift transit).  HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.22(a)(1), which was contained in OSHA inspection number 924666, citation number 1, item number 2, group b, issued on 01/28/2014 and affirmed as a final order on  02/20/2014 with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $21300
  • · Z (R) $39193

1910.22 A02

Repeat Gravity 5 3 instances 4 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $39,193 · Current $21,300 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  a) Plant, Light Weight Foam Molding - Oil leaks from Press #18 were not repaired and the surrounding floors were not cleaned, exposing workers to slip/fall hazards.     b) Plant, Hot Mold Area - Oil leaks from Press #16 were not repaired and the surrounding floors were not cleaned, exposing workers to slip/fall hazards.     c) Plant, Light Weight Foam Molding - Oil leaks from Press #7 were not repaired and the surrounding floors were not cleaned, exposing workers to slip/fall hazards.       HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.22(a)(2), which was contained in OSHA inspection number 924666, citation number 1, item number 2, group a, issued on 01/28/2014 and affirmed as a final order on  02/20/2014 with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $21300
  • · Z (R) $39193

1910.147 C04 I

Repeat Gravity 10 3 instances 5 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $68,591 · Current $39,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Plant, DS Area - On or about 03/08/16 and at times prior thereto employees performed maintenance/repairs on the robotic water jet cutter. The employer did not develop, implement, and utilize a written lockout/tagout procedure to protect workers from moving parts, 480 V electric power, compressed air, and high pressure water jets.   b) Plant, BMW Foam Clamp Area - On or about 03/08/16 and at times prior thereto employees performed troubleshooting of foam clamps #1, #2, #3 and the surrounding equipment, and the employer did not develop, implement, and utilize written lockout/tagout procedures to protect workers from moving parts, 480 V electrical power, hydraulic power, and compressed air.    c) Throughout the Plant - Employees conducted repairs/maintenance of equipment including (but not limited to) the Laroche Tearing Machine, the Baler, Presses in the hot Mold Area, Oven Presses in the Light Weight Foam Molding, Presses in the Light Weight Foam Molding, and additional equipment subjected to lockout/tagout as described in the company inventory of date 04/13/16.  The employer did not utilize written lockout/tagout procedures, exposing employees to electrical energy, steam, compressed air, hydraulic energy, hot surfaces and fluids, potential (gravitational) energy, crushes and amputations.  HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.147(c)(4)(i), which was contained in OSHA inspection number 924666, citation number 1, item number 5, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $39000
  • · Z (R) $68591

1910.147 C06 I

Repeat Gravity 10 1 instance 3 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $68,591 · Current $39,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Throughout the Plant - On or about 03/08/16 and at times prior thereto employees performed repairs, maintenance and re-tooling of equipment under lockout/tagout procedures which include (but are not limited to):  Airlay #3 Bale Breakers, Resin Application Feed 1 and 2 (04/21/09). Airlay #3 Mac Filter Unit (04/21/09). Airlay #3 Bruno Press (04/21/09).           Airlay #3 Slitter (04/21/09).                 Airlay #3 Regrinder (04/21/09).                   Airlay #3 Resin Applicator (04/21/09).          Airlay Line (03/11/14). Bale Breaker 1 and 2 03/11/14). Trash Compactor 1 and 2 (03/11/14). DS Baler (09/03/14). Foam Clamp 1-3 (03/11/14). Foil Press (03/11/14). Hard Layer Press and Oven (03/11/14). Press 2-10 (03/11/14). Oven on Press 2 and 3 (03/11/14). Oven on Press 1 (03/11/14). Oven on Press 2 and 3 (03/11/14). Presses 1 to 3 (03/11/14). Presses 4-6 (03/11/14). Presses 7-10 (03/11/14). Oven on Press 13 (03/11/14). Press 14 (03/11/14). Subaru (03/11/14). T300 Dash (03/11/14). T300 Hood (03/11/14).  The  employer did not conduct periodic and at least annual inspections of the written lockout/tagout procedures. Workers were exposed to electrical energy, steam, compressed air, hydraulic energy, hot surfaces and fluids, potential (gravitational) energy, crushes and amputations.  HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 924666, citation number 1, item number 7, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $39000
  • · Z (R) $68591

1910.147 C07 I A

Repeat Gravity 10 1 instance 3 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $68,591 · Current $39,000 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  a) Throughout the plant - On or about 03/08/16 and at times prior thereto employees performed repairs, maintenance, re-tooling, and cleaning of equipment including (but not limited to):   Laroche Tearing Machine, International Baler, Presses in the hot Mold Area, DS Water Jet Cutter, Oven Presses in the Light Weight Foam Molding, Presses in the Light Weight Foam Molding, and additional equipment subjected to lockout/tagout as described in the company inventory of date 04/13/16.    Employees participating in lockout/tagout were not trained in the recognition of the type and magnitude of the hazardous energies for each specific equipment, and the methods and means necessary for energy isolation. Workers were exposed to electrical energy, steam, compressed air, hydraulic energy, hot surfaces and fluids, potential (gravitational) energy, crushes and amputations.   HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.147(c)(7)(i)(A), which was contained in OSHA inspection number 924666, citation number 1, item number 8, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $39000
  • · Z (R) $68591

1910.212 A01

Repeat Gravity 10 8 instances 10 exposed
Issued
Sep 7, 2016
Abate by
Nov 11, 2016
Penalty
Initial $68,591 · Current $39,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, and rotating parts:  a) Plant, BMW Foam Clamp - On or about 03/08/16 and at times prior thereto employees  were instructed to place their bodies inside presses #1, 2, and 3 to clean the molds between cycles. The light curtains failed to detect the presence of the operators inside the presses.     b) Plant, Airlay - On or about 03/08/16 and at times prior thereto the side of the Laroche tearing machine had an incomplete guard, exposing workers to nip points created by a rotating drum and a spiked roller.    c) Plant, Light Weight Foam Molding - On or about 03/08/16 and at times prior thereto the Oven Press #5 was not guarded to protect employees and other workers from accidental contact with the cycling hot press.   d) Plant, Light Weight Foam Molding - On or about 03/08/16 and at times prior thereto the Oven Press #6 was not guarded to protect employees and other workers from accidental contact with the cycling hot press.   e) Plant, Light Weight Foam Molding - On or about 03/08/16 and at times prior thereto the Oven Press #7 was not guarded to protect employees and other workers from accidental contact with the cycling hot press.   f) Plant, Airlay - On or about 03/08/16 and at times prior thereto the side of the machine was not guarded to prevent contact with the horizontal screw conveyor (auger).  g) Plant, Airlay - On or about 03/08/16 and at times prior thereto the side of the machine was not guarded to prevent contact with the brake rotor.   h) Plant, Light Weight Foam Molding - On or about 03/08/16 and at times prior thereto the light curtains in the back of press #6 failed to detect the presence of the back operator during cycles initiated by the front operator.   HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 924666, citation number 2, item number 1, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $39000
  • · Z (R) $68591

1910.219 F03

Repeat Gravity 10 1 instance 2 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $68,591 · Current $39,000 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:  a) Plant, Airlay - The side door in the regrinder was not locked or interlocked, and opened freely during the operation of the machine exposing workers to the two roller chain and sprocket systems.  HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.219(f)(3), which was contained in OSHA inspection number 924666, citation number 2, item number 2, group c, issued on 01/28/2014 and affirmed as a final order on  02/20/2014 with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $39000
  • · Z (R) $68591

1910.242 B

Repeat Gravity 5 1 instance 2 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $48,994 · Current $27,900 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a) Plant, Airlay - On or about 03/08/16 and at times prior thereto workers cleaned the Airlay equipment with compressed air supplied directly from the plant compressor (100-110 psig). The nozzle was replaced with a straight tube, and the pressure was not regulated.   Pressure measurement: 60 psig (due to losses at the contact point between the tube tip and the rubber seal  in the gage, held by hand).    HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.242(b), which was contained in OSHA inspection number 924666, citation number 2, item number 3, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $27900
  • · Z (R) $48994

1910.303 B02

Repeat 1 instance 1 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $1,958 · Current $1,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Plant, Hot Mold Area - On or about 03/08/16 and at times prior thereto employees utilized a 120 V six-outlet black relocatable power tap (RPT) to connect a printer and an extension cord. The RTP was  placed in service for applications for which it was not originally designed.    HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 924666, citation number 3, item number 2, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $1000
  • · Z (R) $1958

1910.303 B07 IV

Repeat Gravity 10 2 instances 3 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $68,591 · Current $39,000 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  a) Plant, Light Weight Foam Molding - On or about 03/08/16 and at times prior thereto the nominal 208 V dead front panel mounted on a structural steel column (in front of Oven Press #7) was crushed by a forklift and was left energized in service without repair.   b) Plant, Airlay Building - On or about 03/08/16 and at times prior thereto the conduit protecting the power cable in the Laroche machine  was broken and separated in proximity of the strain relief device (480 V motor). Employees were exposed to potential loss of insulation and contact with 480 live parts.   HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.303(b)(7)(iv), which was contained in OSHA inspection number 924666, citation number 1, item number 9, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $39000
  • · Z (R) $68591

1910.305 G01 IV A

Repeat 1 instance 1 exposed
Issued
Sep 7, 2016
Abate by
Oct 11, 2016
Penalty
Initial $1,958 · Current $1,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Plant,  Airlay - On or about 03/08/16 and at times prior thereto the flexible cable carrying power from the regrinder  switch box  to the air blower switch box  was left unprotected and was not mounted inside  a conduit.  Employees were exposed to potential loss of insulation and contact with live parts.                                                                                                                       HP Pelzer Automotive Systems, Inc. was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 924666, citation number 3, item number 4, issued on 01/28/2014 and affirmed as a final order on  02/20/2014, with respect to a workplace located at 1884 Warrenton Hwy, Thomson, GA 30824.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $1000
  • · Z (R) $1958

View HP Pelzer Automotive Systems, INC.'s full OSHA safety record →