Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN MINE DOOR

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICAN MINE DOOR in 6200 HARVARD AVE, CLEVELAND, OH 44104 (NAICS 333131). OSHA activity number 341335792.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Mine Door — free Get an email when a new federal OSHA severe-injury report for American Mine Door is published. One employer, no account, unsubscribe in one click.
Establishment
AMERICAN MINE DOOR
Site address
6200 HARVARD AVE
City
CLEVELAND
State
OH
ZIP
44104
Mailing
6200 HARVARD AVE, CLEVELAND, OH 44104
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333131
Employees
25
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 11, 2016
Abate by
Aug 29, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to a struck by hazard when using a lifting device that was unmarked/not rated:    On or about March 18, 2016, the employer did not ensure safe construction with proper identification, certification and labeling of the under the hook lifting device that was in use for transported coils of steel that range in weight from 7,000 to 9,000 pounds.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.23 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 11, 2016
Abate by
Jul 29, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could not walk directly into the opening:    On or about March 18, 2016, employees were exposed to a fall hazard, in that, an elevated platform 9 feet above the work floor had a vertical ladder opening that did not have a swing gate and was not offset. The elevated platform was in place for servicing and maintaining the Pacific 1000 ton hydraulic press brake.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.179 J02 III

Serious Gravity 5 7 instances 10 exposed
Issued
Jul 11, 2016
Abate by
Aug 13, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed:    On or about March 18, 2016, the employer did not ensure the hoist block hooks on the following overhead cranes were inspected and certified.     a. Conlift Inc., 5 ton #866  b. Conlift Inc., 2 ton #868  c. Conlift Inc., 5 ton #865  d. Conlift Inc., 2 ton #871  e. Rauch Inc. double hoist blocks, 25 ton and 5 ton  f. No manufacture name, 4 ton
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.179 J03

Serious Gravity 5 6 instances 10 exposed
Issued
Jul 11, 2016
Abate by
Aug 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:  On or about March 18, 2016, the employer did not ensure the following overhead cranes were inspected and certified within the past 12 months..   a. Conlift Inc., 5 ton #866 b. Conlift Inc., 2 ton #868 c. Conlift Inc., 5 ton #865 d. Conlift Inc., 2 ton #871 e. Rauch Inc. double hoist blocks, 25 ton and 5 ton f. No manufacture name, 4 ton
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 M01

Serious Gravity 5 6 instances 10 exposed
Issued
Jul 11, 2016
Abate by
Aug 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(m)(1): Thorough monthly inspections of rope conditions, with written, dated and signed reports, were not performed on the running ropes:  On or about March 18, 2016, the employer did not ensure the wire ropes (running ropes) on the following overhead cranes were inspected and certified each month.   a. Conlift Inc., 5 ton #866 b. Conlift Inc., 2 ton #868 c. Conlift Inc., 5 ton #865 d. Conlift Inc., 2 ton #871 e. Rauch Inc. double hoist blocks, 25 ton and 5 ton f. No manufacture name, 4 ton
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 9 instances 4 exposed
Issued
Jul 11, 2016
Abate by
Jul 29, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about March 18, 2016, the following machines had points of operation, rotating parts, ingoing nip points and flying chips and sparks that were not safeguarded.    a. Bridgeport drill press, Millport drill press and American radial arm drill press.  b. Hyd- Mech horizontal bandsaw metal chip auger.  c. Peddinghaus ironworker shear, hole punch, angle cutter, square and round stock cutters.  d. Pacific hydraulic press brake, two Cincinnati and one Engel mechanical powered press brakes. Additionally the treadle/foot pedals for the two Cincinnati press brakes were not guarded against unintentional activation.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.255 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 11, 2016
Abate by
Jul 29, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.255(b)(4): All press welding machine operations, where there was a possibility of the operator's fingers being under the point of operation, were not effectively guarded by use of a device such as an electronic eye safety circuit, two hand controls:     On or about March 18, 2016, employees were exposed to a Taylor Winfield spot welder that was not guarded at the welding tips.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 11, 2016
Abate by
Jul 19, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     On or about March 22, 2016, employees were exposed to an electrical junction knockout box that was attached to an electrical flexible cord. The flexible cord was hanging on the building column behind the American radial arm drill press.        NOTE: Knockout boxes were designed to be secured to a fixed/permanent structure. When knockout boxes are used on the ends of flexible cords, employees gripping the box to attach or disconnect a plug may dislodge the circular scored metal portion in the box wall causing it to come in contact with the hot terminal. The result may lead to an electric shock.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.303 G02 I

Serious Gravity 5 3 instances 4 exposed
Issued
Jul 11, 2016
Abate by
Jul 19, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about March 18, 2016, there were three electrical distribution panels with over current devices (electrical breakers) that were missing. Employees were exposed to the open panels and the live electrical parts.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.37 B05

Other-than-serious 1 instance 4 exposed
Issued
Jul 11, 2016
Abate by
Jul 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  On or about March 18, 2016, the doorway used as a passage between the main buildings was not marked as not an exit.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.179 G01 V

Other-than-serious 1 instance 2 exposed
Issued
Jul 11, 2016
Abate by
Jul 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions:   On or about March 18, 2016, the pendant control for the Conlift 2 ton overhead crane in the east building was had control buttons that were not legible.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View American Mine Door's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341335792.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.