EDGEFIELD, SC ·
OSHA Inspection: U.S. DEPARTMENT OF JUSTICE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF JUSTICE in 501 GARY HILL ROAD, EDGEFIELD, SC 29824 (NAICS 922140). OSHA activity number 341336865.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. DEPARTMENT OF JUSTICE
- Site address
- 501 GARY HILL ROAD
- City
- EDGEFIELD
- State
- SC
- ZIP
- 29824
- Mailing
- 501 GARY HILL ROAD, EDGEFIELD, SC 29824
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922140
- Employees
- 340
- Ownership type
- Federal government (D)
Citations
7 citations on file for this inspection.
1910.132 D01
- Issued
- May 19, 2016
- Abate by
- Jun 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment a) Worksite: While conducting a hazard assessment of the workplace the employer failed to recognize the point of operation hazard and the need to protect workers from making contact with the moving blades of four (4) strip cutter machines. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- · Z (S) $0
1910.212 A03 II
- Issued
- May 19, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Strip Cutting Area in the northwest corner of the UNICOR building: Two (2) TRC 1000 AA cold strip cutter machines did not have guarding to prevent the operators from making contact with the shear type blade while automatically cutting strips of materials for belt loops. b) Strip Cutting Area in the northwest corner of the UNICOR building: Two (2) TRC 1000 AA hot strip cutter machines did not have guarding to prevent the operators from making contact with the heated cutter while automatically cutting strips of materials for belt loops. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- May 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) North wall of the Welding Shop Supervisors Office: A Belkin relocatable power tap designed and listed to provide power to high concentrations of low powered loads such as computers, TVs, stereos, printers, etc. was used to proved power for high powered loads such as a commercial grade refrigerator and a Sharp microwave oven.
Recent events (1)
- · Z (S) $0
1910.304 B02 II
- Issued
- May 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(2)(ii): Receptacles having grounding contacts did not have contacts that were effectively grounded. a) Southeast end of the work floor of the UNICOR building: A receptacle outlet located near the ceiling above a QV Inspection Station supplied power to the station for lighting and equipment was found to have a false ground.
Recent events (1)
- · Z (S) $0
1910.304 G05
- Issued
- May 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) South end of the Welding Shop: The 120 volt electrical cord on a Dayton pedestal fan was missing the ground pin on the end of its' plug-end. b) South wall of the UNICOR Warehouse: The 120 volt electrical cord on a Nova pedestal fan was missing the ground pin on the end of the plug-end. c) Center of the Front Lobby: The 120 volt electrical cord on a Oreck vacuum cleaner used to clean the carpet was found to have a missing ground pin on the plug-end. d) East end of the Laundry Room: The 120 volt electrical cord on a Sanitaire Air Mover was found to have a missing ground pin on the plug-end.
Recent events (1)
- · Z (S) $0
1910.334 A02 I
- Issued
- May 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) QA Station northwest corner of UNICOR work floor: Due to lack of effective visual inspections a 120 volt flexible cord providing power to a fluorescent light was found to be tied into a knot, and was also showing visible damage to the outer insulation showing the insulated wired beneath.
Recent events (1)
- · Z (S) $0
1910.212 A05
- Issued
- May 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: a) South wall of the Camp Recreation Room: Due to the cover over the mechanical/electrical parts of a water cooler having been removed it exposed employees to the unguarded fan blade located inside.
Recent events (1)
- · Z (O) $0
More inspections at U.S. Department of Justice
View U.S. Department of Justice's full OSHA safety record →
More inspections in this industry (NAICS 922140)
More inspections in SC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341336865.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.