BUTLER, PA —
OSHA Inspection: GCL, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of GCL, INC. in 205 KITTANNING STREET, BUTLER, PA 16001 (NAICS 332312). OSHA activity number 341340545.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GCL, INC.
- Site address
- 205 KITTANNING STREET
- City
- BUTLER
- State
- PA
- ZIP
- 16001
- Mailing
- 685 GLENWOOD WAY, BUTLER, PA 16001
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 20
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.106 D04 I
- Issued
- May 20, 2016
- Abate by
- Jun 2, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with noncombustible liquid tight raised seal or ramp at least 4 inches in height. Opening(s) from inside flammable and combustible storage room(s) were not provided with approved self-closing fire doors. The inside flammable and combustible storage room(s) were not liquid-tight where the walls joined the floor: a) In the Spray Finishing Bay, on or about March 22, 2016 - The employer failed to provide a liquid tight raised seal or ramp between the opening of the inside storage room used to store flammable liquids and the spray finishing bay. b) In the Spray Finishing Bay, on or about March 22, 2016 - The employer failed to provide the opening of the inside storage room used to store flammable liquids and the spray finishing bay with an approved self-closing fire door.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.106 D04 III
- Issued
- May 20, 2016
- Abate by
- Jun 9, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(4)(iii): Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), was not approved under subpart S of this part for Class I, Division 2 Hazardous Locations: a) In the Spray Finishing Bay, on or about March 22, 2016 - The employer failed to provide electrical wiring approved for Class I, Division 2 Hazardous Locations in the inside storage room used to store Category 3 flammable liquids with flashpoints below 100 °F (37.8 °C).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 D04 IV
- Issued
- May 20, 2016
- Abate by
- Jun 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(4)(iv): 29 CFR 1910.106(d)(4)(iv): Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system. Such system was not designed to provide for a complete change of air within the room at least six times per hour: a) In the Spray Finishing Bay, on or about March 22, 2016 - The employer failed to provide a ventilation system in the inside storage room used to store flammable liquids.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G02
- Issued
- May 20, 2016
- Abate by
- Jun 2, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a) In the Spray Paint Bay, on or about March 22, 2016 - The employer failed to keep the Spray Paint Bay floor free of an accumulation of Hi-Solids Polyurethane - Gloss (Part S), Ultradeep Base, Product Number B65T304 and Hi-Solids Polyurethane Activator (Part T), Product Number B60V30. The mixture was sprayed onto structural steel and railings.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.134 C01
- Issued
- May 20, 2016
- Abate by
- Jun 2, 2016
- Penalty
- Initial $1,200 · Current $720 Reduced
9135
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) In the Spray Paint Bay, on or about March 22, 2016 - The employer failed to establish and implement a written respiratory protection program for respirator use that was required when employees conducted spray finishing.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.134 E01
- Issued
- May 20, 2016
- Abate by
- Jun 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) In the Spray Paint Bay, on or about March 22, 2016 - The employer failed to provide a medical evaluation to a painter before he was required to wear a half mask air purifying respirator while spray finishing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- May 20, 2016
- Abate by
- Jun 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) In the Spray Paint Bay, on or about March 22, 2016 - The employer failed to fit test a painter who was required to wear a tight-fitting half mask air purifying respirator while spray finishing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- May 20, 2016
- Abate by
- Jun 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) In the Spray Paint Bay, on or about March 22, 2016 - A painter had facial hair that came between the sealing surface of the facepiece of a half mask air purifying respirator that he was required to wear while spray finishing and his face.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K01 I
- Issued
- May 20, 2016
- Abate by
- Jun 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1)(i): The employer did not ensure that each employee could demonstrate knowledge of why the respirator was necessary and how improper fit, usage, or maintenance could compromise the protective effect of the respirator: a) In the Spray Paint Bay, on or about March 22, 2016 - The employer failed to ensure that a painter could demonstrate knowledge of how improper usage of a half mask air purifying respirator required during spray finishing could compromise the protective effect of the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at GCL, INC.
View GCL, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341340545.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.