Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NU-WAY INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NU-WAY INDUSTRIES, INC. in 555 HOWARD AVE., DES PLAINES, IL 60018 (NAICS 332322). OSHA activity number 341343838.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nu-Way Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Nu-Way Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
555 HOWARD AVE.
City
DES PLAINES
State
IL
ZIP
60018
Mailing
555 HOWARD AVE., DES PLAINES, IL 60018
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
230
Ownership type
A

2 citations on file for this inspection.

1910.132 E

Other-than-serious 1 instance 1 exposed
Issued
Jul 27, 2016
Abate by
Aug 15, 2016
Penalty
Initial $3,240 · Current $500 Reduced
29 CFR 1910.132(e): The employer did not remove from service defective or damaged personal protective equipment.    (a) Welding booth - On March 23, 2016, the employer failed to remove damaged gloves from use by an employee performing TIG welding.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $500
  • — Z (S) $3240

1910.147 C06 I

Other-than-serious 1 instance 5 exposed
Issued
Jul 27, 2016
Abate by
Sep 30, 2016
Penalty
Initial $4,050 · Current $3,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    (a) Facility Wide - On March 23, 2016, the employer failed to conduct periodic inspections of the energy control procedures annually to ensure  that the procedures and the requirement of the standard were being followed.       In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $3000
  • — Z (S) $4050

View Nu-Way Industries, INC.'s full OSHA safety record →