DALLAS, TX —
OSHA Inspection: ATRIUM WINDOWS AND DOORS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ATRIUM WINDOWS AND DOORS in 9001 AMBASSADOR ROW, DALLAS, TX 75247 (NAICS 332321). OSHA activity number 341364446.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ATRIUM WINDOWS AND DOORS
- Site address
- 9001 AMBASSADOR ROW
- City
- DALLAS
- State
- TX
- ZIP
- 75247
- Mailing
- 9001 AMBASSADOR ROW, DALLAS, TX 75247
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 470
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 29, 2016
- Abate by
- Sep 9, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, in-going nip points, rotating parts, flying chips and sparks: a) Employee(s) operating reinforcement saw machine were exposed to amputation hazards due to the guards not being effective.
Recent events (2)
- — I (S) $7000
- — Z (S) $7000
1910.147 C06 II
- Issued
- Jul 29, 2016
- Abate by
- Sep 30, 2016
- Penalty
- Initial $38,500 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) The employer did not certify that the periodic inspections were being completed to include: the identity of the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
- — I (S) $5500
- — Z (R) $38500
1910.147 C07 I B
- Issued
- Jul 29, 2016
- Abate by
- Sep 30, 2016
- Penalty
- Initial $38,500 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) On March 24, 2016, affected employees had not been effectively instructed in the purpose and use of the energy control procedure; where at least one (1) employee who operated a reinforcement saw was exposed to struck-by hazards of rotating parts and was not effectively trained on Lockout/Tag-out procedures. THE EMPLOYER WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, 29 CFR 1910.147(c)(7)(i)(B), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1010174, CITATION NUMBER 1, ITEM NUMBER 2 AND WAS AFFIRMED AS A FINAL ORDER ON 06/12/2015, WITH RESPECT TO A WORKPLACE LOCATED AT 930 HENSLEY LANE, WYLIE, TEXAS 75098.
Recent events (2)
- — I (O) $5500
- — Z (R) $38500
More inspections at Atrium Windows and Doors
View Atrium Windows and Doors's full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341364446.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.