BRADENTON, FL —
OSHA Inspection: TB ROOFING & CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TB ROOFING & CONSTRUCTION, LLC in 407 67TH STREET WEST, BRADENTON, FL 34209 (NAICS 238140). OSHA activity number 341392082.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TB ROOFING & CONSTRUCTION, LLC
- Site address
- 407 67TH STREET WEST
- City
- BRADENTON
- State
- FL
- ZIP
- 34209
- Mailing
- 7000 BRYAN DAIRY RD, LARGO, FL 33777
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Apr 25, 2016
- Penalty
- Initial $5,390 · Current $3,773 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a. At the site, a two frame high tubular welded type scaffold had a 4 plank working platform exposing employees to a 13 feet fall hazard, on or about 04/07/2016. b. At the site, a two frame high tubular welded type mobile scaffold had a 3 plank working platform exposing employees to a 13.5 feet fall hazard, on or about 04/07/2016.
Recent events (2)
- — I (S) $3773
- — Z (S) $5390
1926.451 G01
- Issued
- Apr 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. At the site, a two frame high tubular welded type scaffold was not provided with guardrails on all open sides of the working platform exposing employees to a 13 feet fall hazard, on or about 04/07/2016. b. At the site, a two frame high tubular welded type mobile scaffold was not provided with guardrails on all open sides of the working platform exposing employees to a 13.5 feet fall hazard, on or about 04/07/2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Apr 25, 2016
- Penalty
- Initial $2,310 · Current $1,617 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a. At the site, a two frame tubular welded frame scaffold was not provided with an access ladder to the working platform exposing employees to a 13 feet fall hazard, on or about 04/07/2016. b. At the site, a two frame tubular welded frame mobile scaffold was not provided with an access ladder to the working platform exposing employees to a 13.5 feet fall hazard, on or about 04/07/2016.
Recent events (2)
- — I (S) $1617
- — Z (S) $2310
1926.452 W01
- Issued
- Apr 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(w)(1): The mobile scaffold was not braced by cross, horizontal, or diagonal braces, or combination thereof, to prevent racking or collapse of the scaffold and secure vertical members together laterally so as to automatically square and align the vertical members: a. At the site, a two frame high tubular welded type mobile scaffold was not provided with a diagonal brace to maintain the working platform plumb and square, exposing employees to a 13.5 feet fall hazard, on or about 04/07/2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at TB Roofing & Construction, LLC
View TB Roofing & Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341392082.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.