CLEARWATER, FL —
OSHA Inspection: TB ROOFING & CONSTRUCTION LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TB ROOFING & CONSTRUCTION LLC in 101 N GARDEN AVE., CLEARWATER, FL 33756 (NAICS 238140). OSHA activity number 342940954.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TB ROOFING & CONSTRUCTION LLC
- Site address
- 101 N GARDEN AVE.
- City
- CLEARWATER
- State
- FL
- ZIP
- 33756
- Mailing
- 6426 126TH AVE. N., LARGO, FL 33773
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- May 1, 2018
- Penalty
- Initial $18,108 · Current $18,108
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) At the jobsite, employees in the process of removing stucco were exposed to fall hazards up to 20 feet, in that, work platforms on the 3rd and 4th levels of the scaffolding system were not fully planked or decked. Observed on or about 2/12/2018. TB Roofing & Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(b)(1), which was contained in OSHA inspection number 1139208, citation number 1, item number 1A and was affirmed as a final order on 5/19/2016, with respect to a workplace located at 407 67th Street West, Bradenton, Florida.
Recent events (1)
- — Z (R) $18108
1926.451 G01
- Issued
- May 1, 2018
- Penalty
- Initial $18,108 · Current $18,108
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) At the jobsite, employees in the process of removing stucco were exposed to fall hazards up to 20 feet, in that, a guard rail was not installed at the open sides of the work platforms on the 3rd and 4th levels. Observed on or about 2/12/2018. TB Roofing & Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1), which was contained in OSHA inspection number 1139208, citation number 1, item number 1B and was affirmed as a final order on 5/19/2016, with respect to a workplace located at 407 67th Street West, Bradenton, Florida.
Recent events (1)
- — Z (R) $18108
1926.451 C01
- Issued
- May 1, 2018
- Penalty
- Initial $9,054 · Current $9,054
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) At the jobsite, employees in the process of removing stucco were exposed to fall, collapse and struck by hazards, in that, the tubular welded frame scaffolding system (5' deep, 7' wide by 5' high) 5 levels high by 7 columns across was not restrained from tipping. Observed on or about 2/12/2018.
Recent events (1)
- — Z (S) $9054
1926.452 C02
- Issued
- May 1, 2018
- Penalty
- Initial $9,054 · Current $9,054
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) At the jobsite, employees in the process of removing stucco were exposed to fall, collapse and struck by hazards, in that, the tubular welded frame scaffolding system (5' deep, 7' wide by 5' high) 5 levels high by 7 columns across was missing cross bracing on the interior side 3rd column on the 1st, 2nd and 3rd levels. Observed on or about 2/12/2018.
Recent events (1)
- — Z (S) $9054
More inspections at TB Roofing & Construction LLC
View TB Roofing & Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342940954.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.