Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: B & K INSTALLATIONS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of B & K INSTALLATIONS INC. in 246 SW 4TH AVE, HOMESTEAD, FL 33030 (NAICS 332322). OSHA activity number 341394674.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B & K Installations INC. — free Get an email when a new federal OSHA severe-injury report for B & K Installations INC. is published. One employer, no account, unsubscribe in one click.
Site address
246 SW 4TH AVE
City
HOMESTEAD
State
FL
ZIP
33030
Mailing
246 SW 4TH AVE, HOMESTEAD, FL 33030
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
48
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 1 exposed
Issued
Jul 1, 2016
Abate by
Jul 18, 2016
Penalty
Initial $3,273 · Current $2,291 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      a.  On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to caught and struck by hazards while working with a drill press (i.e. Northern Industrial, #066-DP06) that lacked a point of operation guard.     b.  On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to caught and struck by hazards while working with a drill press (i.e. RDM-100, Serial #195392) that lacked a point of operation guard.     c.  On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to caught and struck by hazards while working with a milling machine (i.e. Millport MP2-026) that lacked a point of operation guard.
Recent events (2)
  • — I (S) $2291.1
  • — Z (S) $3273

1910.212 B

Serious Gravity 1 2 instances 1 exposed
Issued
Jul 1, 2016
Penalty
Initial $1,607 · Current $1,125 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving    a.  On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to a struck by hazard while working with a drill press (i.e. Northern Industrial, #066-DP06) which was not anchored.     b.  On or about May 23, 2016, at the interior sheet metal area of above addressed jobsite, an employee was exposed to a struck by hazard while working with a drill press (i.e. RDM-100, Serial #195392) which was not anchored.
Recent events (2)
  • — I (S) $1124.9
  • — Z (S) $1607

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 1, 2016
Penalty
Initial $2,142 · Current $1,499 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     On or about April 13, 2016, at the exterior welding area of above addressed jobsite, an electrical metal junction box (i.e. 4" x 4") was used as part of a job made extension cord, exposing an employee to an electrical hazard.
Recent events (2)
  • — I (S) $1499.4
  • — Z (S) $2142

1910.252 A01 II

Other-than-serious 1 instance 1 exposed
Issued
Jul 1, 2016
Abate by
Jul 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(1)(ii): When the object to be welded or cut could not be moved and all the fire hazards could not be removed, guards were not used to confine the heat, sparks, and slag to protect the immovable fire hazards  On or about May 2, 2016, at the robot welding area of the above addressed jobsite, an employee was exposed to a fire hazard while working in an area next to unguarded (i.e. cardboard boxes, wood, lubricants), located within 13 to 60 inches of a welding area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
Jul 1, 2016
Penalty
Initial $536 · Current $375 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:      On or about May 2, 2016, at the exterior sheet metal area of above addressed jobsite, an employee was exposed to an electrical hazard while operating an Ironworker (i.e. Model IW-65, #6509-24M, 2.0" punch stroke) whose foot pedal lacked strain relief, exposing interior current carrying conductors to employee contact.
Recent events (2)
  • — I (O) $375.2
  • — Z (O) $536

View B & K Installations INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341394674.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.