Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: B & K INSTALLATIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of B & K INSTALLATIONS, INC. in 246 SW 4TH AVE., HOMESTEAD, FL 33030 (NAICS 332999). OSHA activity number 346956287.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B & K Installations, INC. — free Get an email when a new federal OSHA severe-injury report for B & K Installations, INC. is published. One employer, no account, unsubscribe in one click.
Site address
246 SW 4TH AVE.
City
HOMESTEAD
State
FL
ZIP
33030
Mailing
246 SW 4TH AVE., HOMESTEAD, FL 33030
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
32
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 29, 2023
Abate by
Oct 12, 2023
Penalty
Initial $6,641 · Current $3,985 Reduced
29 CFR  1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:     On or about 9/5/2023, at the jobsite located at 246 SW 4th Ave, Homestead, FL 33030, an employee was exposed to struck by and caught by hazards while working with a lathe ( i.e.  Lansing Model T, Serial Number Not available) that lacked a guard on its point of operation.
Recent events (2)
  • — I (S) $3984.6
  • — Z (S) $6641

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 29, 2023
Penalty
Initial $6,641 · Current $3,985 Reduced
29 CFR  1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  On or about 9/5/2023, at the jobsite located at 246 SW 4th Ave, Homestead, FL 33030,  an employee was exposed to a struck by hazard while operating a drill press without wearing safety glasses.
Recent events (2)
  • — I (S) $3984.6
  • — Z (S) $6641

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Sep 29, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  On or about 9/5/2023 and at times prior, at 246 SW 4th Ave, Homestead Florida 33030, a press brake lacked of strain relief where its cord entered into the pedal, exposing an employee to an electrical hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View B & K Installations, INC.'s full OSHA safety record →