OSHA Inspection: KIRK WOOD PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KIRK WOOD PRODUCTS, INC. in 10424 E 1400 NORTH RD, BLOOMINGTON, IL 61705 (NAICS 321920). OSHA activity number 341418721.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kirk Wood Products, INC. — free Get an email when a new federal OSHA severe-injury report for Kirk Wood Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10424 E 1400 NORTH RD
City
BLOOMINGTON
State
IL
ZIP
61705
Mailing
10424 E 1400 NORTH RD, BLOOMINGTON, IL 61705
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.212 A03 II

Other-than-serious 1 instance 2 exposed
Issued
Jun 15, 2016
Abate by
Jun 27, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On or about, April 26, 2014, employees operating the pop-up cut-off saw were exposed to amputations hazards and the employer did not ensure that the two-hand control on the saw, was used appropriately.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1910.213 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 15, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    On or about, April 18, 2016 employees using the table saw were exposed to amputation hazards because the saw was not guarded by a hood that completely enclosed the portion of the saw above the table.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.303 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 15, 2016
Abate by
Jul 5, 2016
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    a) On or about April 26, 2016 employees were exposed to electrical shock and burns while performing work activities near the notcher on the east wall, south of the table saw, because the employer had not ensured that the raceway enclosing the energized conductors was examined to ensure that it was not broken or separated.    b) On or about April 26, 2016 employees were exposed to electrical shock and burns while performing work activities near the Baker Band Resaw, because the employer had not ensured that the raceway enclosing the energized conductors was examined to ensure that it was not broken or separated.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.303 G02 I

Serious Gravity 5 2 instances 4 exposed
Issued
Jun 15, 2016
Abate by
Jul 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) On or about April 26, 2016 employees were exposed to electrical shock and burns while performing work activities near the notcher on the east wall, south of the table saw, and the employer had not ensured that the live insulated conductors were guarded against accidental contact because the nonmetallic raceway mounted to the floor that enclosed the conductors was broken and separated at a joint.  b) On or about April 26, 2016 employees were exposed to electrical shock and burns while performing work activities near the Baker Band Resaw, and the employer had not ensured that the live insulated conductors were guarded against accidental contact because the nonmetallic raceway that enclosed the conductors was separated at the connection going into the switch enclosure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D02

Other-than-serious 1 instance 10 exposed
Issued
Jun 15, 2016
Abate by
Jul 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:  On or about April 22, 2016, the employer did not certify, in writing, that the workplace hazard assessment had been performed as required by the standard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kirk Wood Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341418721.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.