OSHA Inspection: SUNSHINE LAUNDRY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUNSHINE LAUNDRY, INC. in 617 N FLORES ST, SAN ANTONIO, TX 78205 (NAICS 812320). OSHA activity number 341419828.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunshine Laundry, INC. for free Get an email when a new federal OSHA severe-injury report for Sunshine Laundry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
617 N FLORES ST
City
SAN ANTONIO
State
TX
ZIP
78205
Mailing
3323 EAST COMMERCE ST., SAN ANTONIO, TX 78220
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812320
Employees
60
Ownership type
A

6 citations on file for this inspection.

1910.264 C04 III A

Serious Gravity 5 1 instance 40 exposed
Issued
Jul 28, 2016
Abate by
Aug 7, 2016
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.264(c)(4)(iii)(a): Steam pipe(s) in laundry operations and within 7 feet of the floor or working platform, were not insulated or otherwise properly guarded to prevent contact by employees:    Wash Room, on or about April 22, 2016, and at times prior thereto, employees were exposed to steam burns while walking next to an insulated steam line.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.303 B02

Serious Gravity 1 1 instance 40 exposed
Issued
Jul 28, 2016
Penalty
Initial $2,100 · Current $1,700 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Drain Area, on or about April 22, 2016, employees were exposed to electrical shock hazards while using a job made extension cord that was made up of a metal box with receptacle that was not used for intended purpose of being mounted securely on the wall.
Recent events (2)
  • · I (S) $1700
  • · Z (S) $2100

1910.305 B02 I

Serious Gravity 5 1 instance 40 exposed
Issued
Jul 28, 2016
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    Drain Area, on or about April 22, 2016, employees were exposed to electrical shock hazards while using a job made extension cord that was made up of a metal box with receptacle on the end and no cover plate installed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3500

1910.303 C03 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 28, 2016
Abate by
Aug 3, 2016
Penalty
Initial $2,800 · Current $2,200 Reduced
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices were not first spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:    Washer and Dryer Room, On or about April 22, 2016, and time prior thereto, employees where exposed to electrical hazards while using the pendant control on a dryer that had splices on the electrical conductor that were made with wire nuts and electrical tape.
Recent events (2)
  • · I (S) $2200
  • · Z (S) $2800

1910.305 G02 III

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 28, 2016
Abate by
Aug 3, 2016
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:      Washer and Dryer Room, On or about April 22, 2016, and time prior thereto, employees where exposed to electrical hazards while using the pendant control on a dryer that had a disconnected strain relief.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2100

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Jul 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Break Area, on or about April 22, 2016, employees were exposed to electrical hazards while in the break area near an extension cord that was wrapped around a metal pipe and used in a permanent fashion.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Sunshine Laundry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341419828.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.