Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAMGER COATINGS SYSTEMS, INCORPORATED

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CAMGER COATINGS SYSTEMS, INCORPORATED in 364 MAIN STREET, NORFOLK, MA 02056 (NAICS 325510). OSHA activity number 341421840.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Camger Coatings Systems, Incorporated — free Get an email when a new federal OSHA severe-injury report for Camger Coatings Systems, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
364 MAIN STREET
City
NORFOLK
State
MA
ZIP
02056
Mailing
364 MAIN STREET, NORFOLK, MA 02056
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 26, 2016
Abate by
Mar 6, 2017
Penalty
Initial $3,271 · Current $2,453 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:    Production Room:     On April 14, 2006 flammable toluene vapors were ignited potentially by static electricity  resulting in a workplace fire and burn injuries to a worker.     a) The fill pipe for tank 3 was not designed and installed to minimize static electricity. Toluene was allowed to free fall into the tank.        b) Workers were not provided personal protective equipment and clothing consisting of materials that would reduce the occurrence of electrostatic discharges.     c) Procedures were not implemented to ensure there was adequate humidification in production room prior to pumping and mixing flammable liquids.        .
Recent events (2)
  • — I (S) $2453
  • — Z (S) $3271

1910.132 A

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 26, 2016
Abate by
Mar 6, 2017
Penalty
Initial $3,271 · Current $2,453 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    Production Room: Flame resistant protective clothing that provides protection against flash fires was not provided to employees working with flammable liquids.      On October 14, 2016  An employee suffered skin burns when his clothing caught fire after toluene vapors were ignited during tank filling operations.
Recent events (2)
  • — I (S) $2453
  • — Z (S) $3271

View Camger Coatings Systems, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341421840.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.