OSHA Inspection: FTA COLUMBUS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FTA COLUMBUS, LLC in 195 PHILLIPI ROAD, COLUMBUS, OH 43228 (NAICS 493110). OSHA activity number 341431864.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FTA Columbus, LLC — free Get an email when a new federal OSHA severe-injury report for FTA Columbus, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
FTA COLUMBUS, LLC
Site address
195 PHILLIPI ROAD
City
COLUMBUS
State
OH
ZIP
43228
Mailing
195 PHILLIPI ROAD, COLUMBUS, OH 43228
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
12
Ownership type
A

4 citations on file for this inspection.

1910.178 L01 I

Other-than-serious 1 instance 12 exposed
Issued
Aug 9, 2016
Penalty
Initial $5,612 · Current $0 Reduced
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    a. On or about April 27, 2016, the employer did not ensure that employees operating forklifts at the facility were trained and certified on the safe use of the forklifts prior to allowing them to operate.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5612

1910.303 G01

Other-than-serious 3 instances 12 exposed
Issued
Aug 9, 2016
Abate by
Aug 19, 2016
Penalty
Initial $5,612 · Current $0 Reduced
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.    a. Located at the north wall exit to the loading docks in the warehouse: On or about April 27, 2016, the working space in front of the 120/208 volt electrical panel, which fed the forklift battery charger and part of the warehouse lighting, was obstructed by a battery charger.        b. Located on the wall outside the office/break room in the warehouse: On or about April 27, 2016, the working space in front of the 120/208 volt electrical panel, Electrical Panel E, was obstructed by stored equipment, such as a pallet jack and a stand up desk.       c. Located on the north wall of the High End area in the warehouse: On or about April 27, 2016, the access to and working space at the 120/208 volt electrical panel, Electrical Panel A, was blocked by skids of product.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5612

1910.305 B01 II

Other-than-serious 3 instances 12 exposed
Issued
Aug 9, 2016
Abate by
Aug 19, 2016
Penalty
Initial $7,857 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.    a. Located at the north wall exit to the loading docks in the warehouse: On or about April 27, 2016, two unused breaker openings in the dead front cover of the 120/208 volt electrical panel, which fed the forklift battery charger and part of the warehouse lighting, exposed employees to an electrical shock hazard.       b. Located on the wall outside the office/break room in the warehouse: On or about April 27, 2016, one unused breaker opening in the dead front cover of the 120/208 volt electrical panel, Electrical Panel E, exposed employees to an electrical shock hazard.        c. Located on the north wall of the High End area in the warehouse: On or about April 27, 2016, one unused breaker opening in the dead front cover of the 120/208 volt electrical panel, Electrical Panel A, exposed employees to an electrical shock hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7857

1904.40 A

Deleted Other-than-serious 1 instance 12 exposed
Issued
Aug 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): Basic requirement. When an authorized government representative asks for the records you keep under Part 1904, you must provide copies of the records within four (4) business hours.  a. On April 27, 2016, an OSHA compliance officer requested the employers OSHA 300 and 300A injury and illness logs during an inspection on-site. The employer failed to provide the logs to OSHA within four hours.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View FTA Columbus, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341431864.