OAK CREEK, WI —
OSHA Inspection: STELLA & CHEWY'S LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STELLA & CHEWY'S LLC in 111OAKVIEW PARKWAY, OAK CREEK, WI 53154 (NAICS 311111). OSHA activity number 341440253.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STELLA & CHEWY'S LLC
- Site address
- 111OAKVIEW PARKWAY
- City
- OAK CREEK
- State
- WI
- ZIP
- 53154
- Mailing
- 111OAKVIEW PARKWAY, OAK CREEK, WI 53154
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311111
- Employees
- 200
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.119 D02 I C
- Issued
- Sep 29, 2016
- Abate by
- Oct 26, 2016
- Penalty
- Initial $7,496 · Current $5,996 Reduced
0170
General-duty citation text
29 CFR 1910.119(d)(2)(i)(C): Process safety information pertaining to the technology of the process did not include the maximum intended quantity: (a) Process safety information (PSI) defining the maximum intended quantity of anhydrous ammonia was not accurate. Two contradictory maximum intended quantity values of anhydrous ammonia were disclosed by the employer. In a document entitled "Operating Refrigerant Charge Summary" the Total Required System Refrigerant Charge was listed as 33,288 lbs. In a document entitled, "Section II Process Safety Information", the maximum intended inventory was listed as 12,000 lbs.
Recent events (2)
- — I (S) $5996
- — Z (S) $7496
1910.119 D03 I
- Issued
- Sep 29, 2016
- Abate by
- Oct 26, 2016
- Penalty
- Initial $7,496 · Current $0 Reduced
0170
General-duty citation text
29 CFR 1910.119(d)(3)(i): Process safety information pertaining to the equipment in the process did not include the elements specified in 29 CFR 1910.119(d)(3)(i)(A) through (H): (a) The information provided regarding safety systems, specifically addressing ammonia detectors in the plant was not adequately clear and accurate. In the document entitled, "Ammonia Refrigeration System Ammonia Detection", ammonia detectors in the plant were listed as having alarm set points of 25 ppm. However, in the document entitled, "AMMONIA SENSOR LAYOUT", the alarm set point was noted as "ALARM SENSOR SET POINT = 35 ppm". (b) The information provided regarding safety systems, specifically regarding ammonia detectors in the Engine Room was not adequately clear and accurate. In the document entitled, "Ammonia Refrigeration System Ammonia Detection", the low level ammonia detector (item number AS20002) was listed as having a set point of 25 ppm which would activate alarm lights and horns outside of the engine room doors and the emergency exhaust fan in the engine room. However, in the document entitled, "SECTION II PROCESS SAFETY INFORMATION", the alarm set point was stated as "When the ammonia concentration in the machine room exceeds 50 PPM, the ammonia detection system will signal a high level on the indicator panel above the entrance to the machine room." (c) In the document entitled, "Ammonia Refrigeration System Ammonia Detection", the high level ammonia detector (near RCB-2) was identified as item number AS20007, whereas on the control panel in the Engine Room it was identified as AS20008. (d) Process safety information did not include the alarm set point for the GasGuard Vent Line Ammonia Sensor.
Recent events (2)
- — I (O) $0
- — Z (S) $7496
1910.119 F01 II A
- Issued
- Sep 29, 2016
- Abate by
- Oct 26, 2016
- Penalty
- Initial $7,496 · Current $0 Reduced
0170
General-duty citation text
29 CFR 1910.119(f)(1)(ii)(A): The employer did not develop and implement written operating procedures that addressed the consequences of deviations from the operating limits in the covered process: (a) In the Engine Room, the operating procedures for compressors did not adequately address the consequences of deviation for high discharge temperature. For example, the standard operating procedure for "Operation of the High Stage Compressor RC-5", did not address the consequences of deviation for high discharge temperature. These consequences could include compressor damage and release of ammonia.
Recent events (2)
- — I (O) $0
- — Z (S) $7496
1910.119 F03
- Issued
- Sep 29, 2016
- Abate by
- Oct 26, 2016
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.119(f)(3): The operating procedures were not reviewed as often as necessary to assure that they reflect current operating practice, including changes that result from changes in process chemicals, technology, and equipment, and changes to facilities: (a) In the Engine Room, the operating procedure for the "Operation of the High Stage Compressor RC-5", which listed a normal operations range for discharge temperature of 75° F to 95° F, did not reflect current operating practice. For the entire month of July, 2016, as documented on the "Compressor RC-5 Daily Check Log Sheet", recorded discharge temperatures that ranged from 176.1° F to 186.2° F. (b) In the Engine Room, the operating procedure for the "Operation of the -20° Low Temp Recirculator, V-6 and Ammonia Pumps AP-5 and AP-6", which listed normal operations range for liquid pumps (AP-5 and AP-6) discharge pressure of 35 to 40 psig, did not reflect current operating practice. For the entire month of July, 2016, as documented on the "Ammonia System Daily Check Log Sheet", recorded discharge pressures for these pumps that ranged from 47 to 59 psig.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 M01
- Issued
- Sep 29, 2016
- Abate by
- Oct 26, 2016
- Penalty
- Initial $7,496 · Current $0 Reduced
0170
General-duty citation text
29 CFR 1910.119(m)(1): The employer did not investigate each incident which resulted in, or could reasonably have resulted in a catastrophic release of highly hazardous chemical in the workplace: (a) The employer did not investigate, in accordance with the requirements of this standard, the ammonia leak incident involving Freeze Dryer FD-6, which occurred on or around February 9, 2016, in the Freeze Dryer Area.
Recent events (2)
- — I (S) $0
- — Z (S) $7496
1910.119 N
- Issued
- Sep 29, 2016
- Abate by
- Oct 26, 2016
- Penalty
- Initial $0 · Current $0
0170
General-duty citation text
29 CFR 1910.119(n): The emergency action plan did not contain procedures for handling small releases: (a) Procedures had not been developed to handle small releases of anhydrous ammonia refrigerant and criteria had not been developed for classifying releases of anhydrous ammonia. Covered employees were not aware of how to classify a release of anhydrous ammonia.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Sep 29, 2016
- Penalty
- Initial $7,496 · Current $5,996 Reduced
0170
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) In the Engine Room, workers' eyes and bodies were potentially exposed to anhydrous ammonia, a corrosive chemical. There was not suitable provision of emergency eyewash and safety shower, in-that there was no emergency eyewash and safety shower installed just outside the engine room's exit door (in accordance with IIAR Bulletin 109).
Recent events (2)
- — I (S) $5996
- — Z (S) $7496
More inspections at Stella & Chewy'S LLC
View Stella & Chewy'S LLC's full OSHA safety record →
More inspections in this industry (NAICS 311111)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341440253.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.