Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SEAGRAVE FIRE APPARATUS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SEAGRAVE FIRE APPARATUS in 105 E. 12TH ST., CLINTONVILLE, WI 54929 (NAICS 336120). OSHA activity number 341443307.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Seagrave Fire Apparatus — free Get an email when a new federal OSHA severe-injury report for Seagrave Fire Apparatus is published. One employer, no account, unsubscribe in one click.
Site address
105 E. 12TH ST.
City
CLINTONVILLE
State
WI
ZIP
54929
Mailing
105 E. 12TH ST., CLINTONVILLE, WI 54929
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336120
Employees
285
Ownership type
A

3 citations on file for this inspection.

1910.252 A02 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 28, 2016
Abate by
Aug 25, 2016
Penalty
Initial $3,400 · Current $2,380 Reduced
29 CFR 1910.252(a)(2)(vii): Relocation of combustibles. Where practicable, all combustibles shall be relocated at least 35 feet (10.7 m) from the work site. Where relocation is impracticable, combustibles shall be protected with flameproofed covers or otherwise shielded with metal or asbestos guards or curtains.  a.  On or about May 3, 2016, an employee was welding on a painted ladder within 35 feet of unprotected combustible material in the Northwest corner of the old building at a facility located at 105 E. 12th Street Clintonville, WI 54929.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.107 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 28, 2016
Abate by
Aug 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c)(2): Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.  a.  On or about May 3, 2016, an employee was welding on a painted ladder that was not separated by a partition from a spraying area less than 20 feet away in the Northwest corner of the old building at a facility located at 105 E. 12th Street Clintonville, WI 54929.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 28, 2016
Abate by
Aug 25, 2016
Penalty
Initial $4,250 · Current $2,975 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  a.  On or about May 6, 2016, the employer did not provide fall protection to an employee when he was adjusting a ladder on top of the "test truck" approximately eight feet above the concrete floor in the Northwest corner of the old building at the Seagrave Fire Apparatus facility located at 105 E. 12th Street Clintonville, WI 54929.
Recent events (2)
  • — I (S) $2975
  • — Z (S) $4250

View Seagrave Fire Apparatus's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341443307.