CLINTONVILLE, WI —
OSHA Inspection: SEAGRAVE FIRE APPARATUS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SEAGRAVE FIRE APPARATUS in 105 E. 12TH ST., CLINTONVILLE, WI 54929 (NAICS 336120). OSHA activity number 341443307.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEAGRAVE FIRE APPARATUS
- Site address
- 105 E. 12TH ST.
- City
- CLINTONVILLE
- State
- WI
- ZIP
- 54929
- Mailing
- 105 E. 12TH ST., CLINTONVILLE, WI 54929
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336120
- Employees
- 285
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.252 A02 VII
- Issued
- Jul 28, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $3,400 · Current $2,380 Reduced
General-duty citation text
29 CFR 1910.252(a)(2)(vii): Relocation of combustibles. Where practicable, all combustibles shall be relocated at least 35 feet (10.7 m) from the work site. Where relocation is impracticable, combustibles shall be protected with flameproofed covers or otherwise shielded with metal or asbestos guards or curtains. a. On or about May 3, 2016, an employee was welding on a painted ladder within 35 feet of unprotected combustible material in the Northwest corner of the old building at a facility located at 105 E. 12th Street Clintonville, WI 54929.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.107 C02
- Issued
- Jul 28, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(2): Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition. a. On or about May 3, 2016, an employee was welding on a painted ladder that was not separated by a partition from a spraying area less than 20 feet away in the Northwest corner of the old building at a facility located at 105 E. 12th Street Clintonville, WI 54929.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 A
- Issued
- Jul 28, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a. On or about May 6, 2016, the employer did not provide fall protection to an employee when he was adjusting a ladder on top of the "test truck" approximately eight feet above the concrete floor in the Northwest corner of the old building at the Seagrave Fire Apparatus facility located at 105 E. 12th Street Clintonville, WI 54929.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
More inspections at Seagrave Fire Apparatus
View Seagrave Fire Apparatus's full OSHA safety record →
More inspections in this industry (NAICS 336120)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341443307.