OSHA Inspection: PROTHERAPY SUPPLIES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PROTHERAPY SUPPLIES in 1750 BRECKINRIDGE PARKWAY SUITE 200, DULUTH, GA 30096 (NAICS 423490). OSHA activity number 341443653.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Protherapy Supplies for free Get an email when a new federal OSHA severe-injury report for Protherapy Supplies is published. One employer, no account, unsubscribe in one click.
Establishment
PROTHERAPY SUPPLIES
Site address
1750 BRECKINRIDGE PARKWAY SUITE 200
City
DULUTH
State
GA
ZIP
30096
Mailing
1750 BRECKINRIDGE PARKWAY SUITE 200, DULUTH, GA 30096
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423490
Employees
40
Ownership type
A

3 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 2, 2016
Abate by
Jun 28, 2016
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1910.23(c)(1): 29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3) of this section) on all open sides:  a.  1750 Breckinridge Parkway, Suite 200, Duluth, GA (Throughout Shop Area) - Employees were exposed to fall hazard.  Employees are required to retrieve and stock materials from the metal storage racks. Employees are climbing and standing onto the metal storage racks approximately 6-20ft. above ground level, to retrieve storage items, without utilizing fall protection, on or about 05/03/16.
Recent events (2)
  • · I (S) $3430
  • · Z (S) $4900

1910.26 C03 VII

Serious Gravity 1 1 instance 6 exposed
Issued
Jun 2, 2016
Abate by
Jun 28, 2016
Penalty
Initial $1,785 · Current $1,249 Reduced
29 CFR 1910.26(c)(3)(vii): Ladders were used as a brace, skid, guy or gin pole, gangway, or for other uses than that for which they were intended, unless specifically recommended for use by the manufacturer:  a.  1750 Breckinridge Parkway, Suite 200, Duluth, GA (Throughout Shop Area) -  Employees were exposed to fall hazard.  Employees were using the 8ft. self-supporting A-frame ladders as a extension ladder to retrieve storage materials from the storage racks.  The ladders were not used in the manner that the manufacture intended, on or about 05/03/16.
Recent events (2)
  • · I (S) $1249
  • · Z (S) $1785

1910.305 G01 IV A

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 2, 2016
Abate by
Jun 28, 2016
Penalty
Initial $1,785 · Current $1,249 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a.  1750 Breckinridge Parkway, Suite 200, Duluth, GA (Throughout Shop Area) - Employees were exposed to electrical hazard.  Flexible extension cord was used as a replacement for permanent wiring running to the overhead lighting fixtures. throughout the building.  The flexible extension cords were not in a metal conduit to prevent outer insulation damage, on or about 05/03/13.