OSHA Inspection: HANKINS LUMBER COMPANY, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of HANKINS LUMBER COMPANY, INC. in 496 EAST NAT G. TROUTT ROAD, GRENADA, MS 38901 (NAICS 321113). OSHA activity number 341465169.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hankins Lumber Company, INC. for free Get an email when a new federal OSHA severe-injury report for Hankins Lumber Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
496 EAST NAT G. TROUTT ROAD
City
GRENADA
State
MS
ZIP
38901
Mailing
P.O. BOX 1397, GRENADA, MS 38901
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
200
Ownership type
Private (A)

5 citations on file for this inspection.

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 18, 2016
Abate by
Oct 28, 2016
Penalty
Initial $5,451 · Current $2,900 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    (a) Boiler Room, Southwest Side - On or about May 12, 2016 a rotating shaft located at the motor on the backside of the under air fire fan lacked a guard exposing an employee to he hazard of being entangled in the rotating shaft.
Recent events (2)
  • · I (S) $2900
  • · Z (S) $5451

1910.219 D01

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 18, 2016
Abate by
Oct 28, 2016
Penalty
Initial $5,451 · Current $3,100 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a) Kiln No. 2, Control Room - On or about May 5, 2016 air compressor with rotating belt and pulley was not guarded    (b) Boiler Room, Southwest Side - On or about May 12, 2016 there was a unguarded belt and pulley at the backside under air fire fan.
Recent events (2)
  • · I (S) $3100
  • · Z (S) $5451

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 18, 2016
Abate by
Oct 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:   (a) Kiln No. 2, Control Room - On or about May 5, 2016 air compressor with rotating belt and pulley was not guarded  (b) Boiler Room, Southwest Side - On or about May 12, 2016 there was a unguarded belt and pulley at the backside under air fire fan.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV B

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 18, 2016
Abate by
Oct 28, 2016
Penalty
Initial $4,089 · Current $3,200 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables may not be used where run through holes in walls, ceilings or floors:    (a) Kiln No. 2, Control Room - On or about May 13, 2016 flexible cords were being run through metal wall.
Recent events (2)
  • · I (S) $3200
  • · Z (S) $4089

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Oct 18, 2016
Abate by
Jan 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a)  Chemical Room - On or about May 12, 2016 the employer had not developed and documented a written hazard communication program for employees using chemicals such as, but not limited to, Chem Aqua, oxygen, acetylene, gasoline and diesel.