Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: PARK AEROSPACE TECHNOLOGIES CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PARK AEROSPACE TECHNOLOGIES CORP. in 486 NORTH OLIVER ROAD, NEWTON, KS 67114 (NAICS 336413). OSHA activity number 341491868.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Park Aerospace Technologies Corp. for free Get an email when a new federal OSHA severe-injury report for Park Aerospace Technologies Corp. is published. One employer, no account, unsubscribe in one click.
Site address
486 NORTH OLIVER ROAD
City
NEWTON
State
KS
ZIP
67114
Mailing
486 NORTH OLIVER ROAD, NEWTON, KS 67114
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
83
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 10, 2016
Abate by
Nov 1, 2016
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points, and rotating parts:  On or about May 18, 2016 - Employees engaged in production activities at the AJ Treater Solution Coating and Dryer machine located in the Rewind Room were exposed to caught-between and amputation hazards in that machine guarding was not provided and utilized at ingoing nip points associated with the rollers.    29 CFR 1903.19(d)(1) requires certification and documentation that the abatement of the above violation is complete.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $7000

1910.147 C06 II

Other-than-serious 1 instance 3 exposed
Issued
Jun 10, 2016
Abate by
Jul 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  Periodic inspections of energy control procedures for equipment such as but not limited to the Treater Oven (1615), and the TJ Treater - Solution Coating & Dryer machine were not documented.   29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 3 exposed
Issued
Jun 10, 2016
Abate by
Jul 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  in the Rewind Room - a 24 Volt power box for the converter of the pneumatic break was missing a knock-out.   29 CFR 1903.19(c)(1) requires certification that the abatement of the above violation is complete.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Park Aerospace Technologies Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341491868.