ANNA MARIA, FL ·
OSHA Inspection: GARY T. BRINGMAN ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GARY T. BRINGMAN ROOFING, INC. in 210 ARCHER WAY, ANNA MARIA, FL 34216 (NAICS 238160). OSHA activity number 341492106.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARY T. BRINGMAN ROOFING, INC.
- Site address
- 210 ARCHER WAY
- City
- ANNA MARIA
- State
- FL
- ZIP
- 34216
- Mailing
- 1111 29TH AVENUE WEST, BRADENTON, FL 34205
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- May 31, 2016
- Penalty
- Initial $4,400 · Current $2,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For employees working at 210 Archer Way located in Anna Maria Island, as observed on or about 19 may, 2016. Employees were installing roofing material on a low slope residential roof without the use of any type of personal fall arrest system. Eave to ground height measured approximately 8 feet 6 inches. Gary T. Bringman Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 316417716, citation number 01, item number 001 and was affirmed as a final order on 3/26/2012, with respect to a workplace located at 1435 Westway Drive, Sarasota, FL 34236.
Recent events (2)
- · I (R) $2200
- · Z (R) $4400
1926.1053 B01
- Issued
- May 31, 2016
- Penalty
- Initial $11,000 · Current $5,500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) For employees working at 210 Archer Way located in Anna Maria Island, as observed on or about 19 may, 2016. Employees were installing roofing material on a low slope residential roof. Employees were using an extension ladder to gain access to the upper landing surface. The ladder side rails were not extended a minimum of 3 feet above the upper landing surface. Eave to ground height measured approximately 8 feet 6 inches. Gary T. Bringman Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 471039, citation number 01, item number 001 and was affirmed as a final order on 7/16/2012, with respect to a workplace located at 1435 Westway Drive, Sarasota, FL 34236. Gary T. Bringman Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 316417716, citation number 01, item number 002a and was affirmed as a final order on 3/26/2012, with respect to a workplace located at 1435 Westway Drive, Sarasota, FL 34236.
Recent events (2)
- · I (R) $5500
- · Z (R) $11000
More inspections at Gary T. Bringman Roofing, INC.
View Gary T. Bringman Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341492106.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.