Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: WYMAN-GORDON COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of WYMAN-GORDON COMPANY in 244 WORCESTER ST, GRAFTON, MA 01519 (NAICS 332111). OSHA activity number 341493161.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wyman-Gordon Company for free Get an email when a new federal OSHA severe-injury report for Wyman-Gordon Company is published. One employer, no account, unsubscribe in one click.
Site address
244 WORCESTER ST
City
GRAFTON
State
MA
ZIP
01519
Mailing
244 WORCESTER ST, GRAFTON, MA 01519
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332111
Employees
435
Ownership type
Private (A)

2 citations on file for this inspection.

1910.134 K

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 28, 2016
Abate by
Sep 1, 2016
Penalty
Initial $4,000 · Current $4,000

Hazardous substances 9020

29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  On or about 5/23/16, employees in the cold flash cutting area were required by the employer to wear powered air-purifying respirators (PAPR) and the employer did not provide comprehensive training.
Recent events (1)
  • · Z (S) $4000

1910.1001 J05 I

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 28, 2016
Abate by
Aug 3, 2016
Penalty
Initial $4,000 · Current $4,000

Hazardous substances 9020

29 CFR 1910.1001(j)(5)(i): The employer did not affix signs or labels so that employees would be notified of what materials contain ACM and/or PACM to materials that were previously identified to be ACM and/or PACM:  On or about 5/23/16, employees were working in the cold flash cutting area, which had asbestos containing material (ACM) on areas such as, but not limited to, a wall, and the employer did not affix signs or labels so that they would be notified of what materials contain ACM and/or PACM.
Recent events (1)
  • · Z (S) $4000

View Wyman-Gordon Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341493161.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.