NORTH GRAFTON, MA ·
OSHA Inspection: WYMAN-GORDON COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WYMAN-GORDON COMPANY in 244 WORCESTER ST, NORTH GRAFTON, MA 01536 (NAICS 332112). OSHA activity number 347994105.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WYMAN-GORDON COMPANY
- Site address
- 244 WORCESTER ST
- City
- NORTH GRAFTON
- State
- MA
- ZIP
- 01536
- Mailing
- 244 WORCESTER STREET, NORTH GRAFTON, MA 01536
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332112
- Employees
- 188
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 29, 2025
- Abate by
- May 30, 2025
- Penalty
- Initial $14,895 · Current $7,448 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: 244 Worcester St, North Grafton, MA: On and before January 23, 2025, some machines, including the VMC10 CNC machine, did not have a documented energy control procedure. Additionally, not all employees utilized the energy control procedures when performing maintenance and servicing activities.
Recent events (2)
- · I (S) $7447.5
- · Z (S) $14895
1910.147 C06 I
- Issued
- Jan 29, 2025
- Abate by
- May 30, 2025
- Penalty
- Initial $4,255 · Current $2,128 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: 244 Worcester St, North Grafton, MA: On and for more than two years before January 23, 2025, the employer had not performed a comprehensive periodic inspection of energy control procedures for all multi-energy sources machines, including the Loewy 50K Press machine, at least annually, to verify that each procedure was adequate and being properly used by employees. Wyman-Gordon Company was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1475557, citation number 1, item number 1 and was affirmed as a final order on October 14, 2020, with respect to a workplace located at 244 Worcester St, North Grafton, MA. *Abatement Notes: A periodic inspection shall include the following elements: - Appointment of an authorized employee to inspect each local procedure for inaccuracies or employee deviations during energy control tasks - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act.
Recent events (2)
- · I (R) $2127.5
- · Z (R) $4255
More inspections at Wyman-Gordon Company
View Wyman-Gordon Company's full OSHA safety record →
More inspections in this industry (NAICS 332112)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347994105.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.