Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of GENERAL LIGHTING & SIGN SERVICES, INC in 7930 NW EXPRESSWAY, OKLAHOMA CITY, OK 73132 (NAICS 238210). OSHA activity number 341503589.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Lighting & Sign Services, INC — free Get an email when a new federal OSHA severe-injury report for General Lighting & Sign Services, INC is published. One employer, no account, unsubscribe in one click.
Site address
7930 NW EXPRESSWAY
City
OKLAHOMA CITY
State
OK
ZIP
73132
Mailing
2701 NW 1ST ST, OKLAHOMA CITY, OK 73107
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
20
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Sep 28, 2016
Abate by
Oct 6, 2016
Penalty
Initial $12,471 · Current $0 Reduced
29 CFR 1926.416(a)(1): The employer permitted an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, without the employee being protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.    This violation occurred on or about May 24, 2016, and at times prior thereto, at 7930 NW Expressway, Oklahoma City and other stores throughout Oklahoma City, the employer did not ensure employees, required to remove neon lighting equipment and install LED lighting equipment, deenergize the electrical energy sources exposing employees to the hazards of coming into contact with energized equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12471

1926.1203 A

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 28, 2016
Abate by
Dec 15, 2016
Penalty
Initial $12,471 · Current $8,000 Reduced
29 CFR 1926.1203(a): Before it begins work at a worksite, each employer did not ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary.      This violation occurred on or about May 24, 2016, and at times prior to, at 7930 NW Expressway, Oklahoma City, General Lighting & Sign Service, Inc. did not have a competent person identify the overhead crawl spaces as confined spaces or consider and evaluate the crawls spaces as possible permit-required confined spaces.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $12471

1926.1207 A

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 28, 2016
Abate by
Dec 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1207(a): The employer did not provide training to each employee whose work is regulated by this standard, at no cost to the employee, and ensure that the employee possesses the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this standard. This training must result in an understanding of the hazards in the permit space and the methods used to isolate, control or in other ways protect employees from these hazards, and for those employees not authorized to perform entry rescues, in the dangers of attempting such rescue.    This violation occurred on or about May 24, 2016, and at times prior to, at 7930 NW Expressway, Oklahoma City, General Lighting & Sign Service, Inc employees required to work in a permit-required confined space were not provided with training to safely perform live electrical work exposing employees to the hazards of coming into contact with live electrical conductors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0