OSHA Inspection: GENERAL LIGHTING & SIGN SERVICES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GENERAL LIGHTING & SIGN SERVICES, INC. in 6509 W. RENO AVE, OKLAHOMA CITY, OK 73127 (NAICS 238990). OSHA activity number 346332216.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Lighting & Sign Services, INC. — free Get an email when a new federal OSHA severe-injury report for General Lighting & Sign Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6509 W. RENO AVE
City
OKLAHOMA CITY
State
OK
ZIP
73127
Mailing
2701 NW 1ST STREET, OKLAHOMA CITY, OK 73107
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
13
Ownership type
A

5 citations on file for this inspection.

1910.333 C03 I A

Serious Gravity 10 1 instance 1 exposed
Issued
May 1, 2023
Abate by
May 8, 2023
Penalty
Initial $6,250 · Current $6,250
29 CFR  1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location was not such that the person and the longest conductive object he or she could contact came closer to any unguarded, energized overhead line than the following distances:    (1)  For voltages to ground 50kV or below - 10 feet (305 cm); (2)  For voltages to ground over 50kV - 10 feet (305 cm) plus 4 inches (10 cm) for every 10kV over 50kV.   On or about November 4, 2022, and at times prior there to, an unqualified employee elevated in an aerial lift basket held a conductive object that came closer than 10 feet to an energized overhead power line, exposing the employee to an electrical shock hazard.
Recent events (2)
  • — I (S) $6250
  • — Z (S) $6250

1910.333 C06

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 1, 2023
Abate by
May 8, 2023
Penalty
Initial $6,250 · Current $0 Reduced
29 CFR 1910.333(c)(6): Conductive materials and equipment that were in contact with an employee's body were not handled in a manner that would prevent them from contacting exposed energized conductors or circuit parts:   On or about November 4, 2022, and at times prior there to, an employee held a conductive object that was not handled in a manner to prevent contacting an exposed energized overhead power line, exposing the employee to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6250

1904.7 B03

Other-than-serious 1 instance 13 exposed
Issued
May 1, 2023
Abate by
May 8, 2023
Penalty
Initial $893 · Current $0 Reduced
29 CFR 1904.7(b)(3): Recording a work-related injury or illness that results in days away from work.  When an injury or illness involved one or more days away from work occurred, the employer did not record the injury or illness on the OSHA 300 Log with a check mark in the space for cases involving days away and an entry of the number of calendar days away from work in the number of days column.  For cases where the employee was out for an extended period of time, the employer did not update the day count when the actual number of days was known:  On or about March 31, 2023, and at times prior there to, the number of days away from work at column (K) were not marked on the year 2022 OSHA Form 300, for case no. 2, work-related burn injuries occurring on 11/4/2022 when working near overhead powerlines.
Recent events (2)
  • — I (O) $0
  • — Z (O) $893

1904.29 B02

Other-than-serious 1 instance 13 exposed
Issued
May 1, 2023
Abate by
May 8, 2023
Penalty
Initial $893 · Current $0 Reduced
29 CFR 1904.29(b)(2): The employer did not fill out or correctly fill out an OSHA Form 301 or equivalent for each recordable injury or illness.   On or about March 31, 2023, and at times prior there to, the employer did not fill out an OSHA Form 301 or equivalent, for case no. 2 on the year 2022 OSHA Form 300, work-related burn and cut injuries occurring on 11/4/2022, from electrical shock, that was classified as days away from work.
Recent events (2)
  • — I (O) $0
  • — Z (O) $893

1904.40 A

Deleted Other-than-serious 3 instances 13 exposed
Issued
May 1, 2023
Abate by
May 8, 2023
Penalty
Initial $893 · Current $0 Reduced
29 CFR  1904.40(a): The employer did not provide an authorized government representative the records with in the four (4) business hours.    On or about March 31, 2023, and at times prior there to, the employer did not provide to OSHA, within the four business hours of when they were requested, the following:  a.  OSHA Form 300 or equivalent for years 2022, 2021, and 2020 b.  OSHA Form 300A or equivalent for years 2022, 2021, and 2020
Recent events (2)
  • — I (O) $0
  • — Z (O) $893

View General Lighting & Sign Services, INC.'s full OSHA safety record →