PHILADELPHIA, PA ·
OSHA Inspection: AC LINEN SUPPLY, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AC LINEN SUPPLY, LLC. in 7831 BARTRAM AVENUE, PHILADELPHIA, PA 19153 (NAICS 812320). OSHA activity number 341508901.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AC LINEN SUPPLY, LLC.
- Site address
- 7831 BARTRAM AVENUE
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19153
- Mailing
- 18 NORTH JERSEY AVENUE, ATLANTIC CITY, NJ 08401
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812320
- Employees
- 125
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Sep 19, 2016
- Abate by
- Sep 23, 2016
- Penalty
- Initial $12,471 · Current $8,730 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Jobsite - The employer did not have specific lock out tag out procedures to protect employees engaged in repair operations from amputation hazards. Observed on or about 18 APR 2016.
Recent events (2)
- · I (S) $8729.7
- · Z (S) $12471
1910.147 C06 I
- Issued
- Sep 19, 2016
- Abate by
- Sep 23, 2016
- Penalty
- Initial $8,908 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) Jobsite - The employer did not ensure that periodic inspections of lockout tagout procedures had been performed, and did not maintain certification for those procedures. Noted on or about 18 APR 2016.
Recent events (2)
- · I (S) $0
- · Z (S) $8908
1910.147 D03
- Issued
- Sep 19, 2016
- Abate by
- Sep 23, 2016
- Penalty
- Initial $12,471 · Current $8,730 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) Jobsite - The employer did not ensure that employees performing servicing and maintenance in a non-routine manner on a Chicago Edge Ultra Maxx Laundry Feeder were protected from an unexpected startup before entering the machine by utilizing locks, blocks, or similar devices. Observed on or about 18 APR 2016.
Recent events (2)
- · I (S) $8729.7
- · Z (S) $12471
1910.303 B02
- Issued
- Sep 19, 2016
- Abate by
- Sep 26, 2016
- Penalty
- Initial $7,126 · Current $4,988 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Jobsite - A wall outlet box was not installed in accordance to its listing and labeling exposing employees to electrical hazards. Condition were observed on or about 18 APR 2016.
Recent events (2)
- · I (S) $4988.2
- · Z (S) $7126
More inspections at AC Linen Supply, LLC.
View AC Linen Supply, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 812320)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341508901.