SOUTH CHARLESTON, WV —
OSHA Inspection: IBC CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of IBC CORPORATION in 340 SECOND AVENUE, SOUTH CHARLESTON, WV 25303 (NAICS 238160). OSHA activity number 341509321.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IBC CORPORATION
- Site address
- 340 SECOND AVENUE
- City
- SOUTH CHARLESTON
- State
- WV
- ZIP
- 25303
- Mailing
- 800 C GREENBRIER STREET, CHARLESTON, WV 25311
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Jun 8, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $2,400 · Current $1,560 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. (a) South Charleston, WV: On or about May 27, 2016 and times prior, an employee using a Bostitch pneumatic nail gun to secure furring strips to a roof prior to applying metal panels was wearing sunglasses that did not offer protection against flying fragments from nails or other materials.
Recent events (2)
- — I (S) $1560
- — Z (S) $2400
1926.20 B02
- Issued
- Jun 8, 2016
- Abate by
- Jun 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s). (a) South Charleston, WV: On or about May 27, 2016 and times prior, inspections and/or audits of the worksite were not required or performed by the employer to identify and correct hazards presented on the worksite, such as eye hazards, fall hazards, and electrical shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 B01 III
- Issued
- Jun 8, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $2,400 · Current $1,560 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. (a) South Charleston, WV: On or about May 27, 2016 and times prior, employees were using a Porter Cable 7 1/4 inch, 15 amp circular saw to cut furring strips without a ground fault circuit interrupter. Power to the circular saw was being provided by a 2 prong, 100ft. extension cord that was plugged into an internal outlet of the residential home of which was not equipped with a ground fault circuit interrupter.
Recent events (2)
- — I (S) $1560
- — Z (S) $2400
1926.501 B13
- Issued
- Jun 8, 2016
- Abate by
- Jun 16, 2016
- Penalty
- Initial $2,400 · Current $1,560 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). (a) South Charleston, WV: On or about May 27, 2016 and times prior, employees were exposed to falls of 11 foot to the uneven ground while applying furring strips and metal panels to a 6/12 pitched residential roof without the use of a fall protection system.
Recent events (2)
- — I (S) $1560
- — Z (S) $2400
1926.503 A01
- Issued
- Jun 8, 2016
- Abate by
- Jun 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. (a) South Charleston, WV: On or about May 27, 2016 and times prior, employees required to prepare a 6:12 pitched roof for the installation of a metal roof were exposed to falls up to 11 foot to the ground and were not trained on the hazards of working from heights and/or the procedures to follow to protect themselves.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at IBC Corporation
View IBC Corporation's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341509321.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.