BRYAN, TX —
OSHA Inspection: STELINDA CONTRACTORS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STELINDA CONTRACTORS in 2909 WEST SH 21, BRYAN, TX 77803 (NAICS 238120). OSHA activity number 341526804.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STELINDA CONTRACTORS
- Site address
- 2909 WEST SH 21
- City
- BRYAN
- State
- TX
- ZIP
- 77803
- Mailing
- 16830 MACEY ROAD, HEARNE, TX 77859
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.404 F06
- Issued
- Jul 6, 2016
- Abate by
- Jul 12, 2016
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: On or about May 25, 2016 and in time prior thereto, a yellow extension cords used to power hand tool used in steel erection did not have a grounding prong, exposing iron workers to an electrical hazard.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.405 G02 III
- Issued
- Jul 6, 2016
- Abate by
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: On or about May 25, 2016 and in times prior thereto an extension cord leading to the roof was spliced, exposing steel erection workers to an electrical hazard. The splice was located under the roof structure of the building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.602 C01 II
- Issued
- Jul 6, 2016
- Abate by
- Jul 12, 2016
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.602(c)(1)(ii): Modifications or additions affecting the safe operation of the equipment were made without the manufacturer's written approval:Note: If such modifications or changes were made, the capacity, operation, and maintenance instruction plates, tags, or decals should have been changed accordingly. On or about May 25, 2016 and in times prior thereto, a job made man basket was used by iron workers to access the roof, exposing them to a fall from elevation hazard.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections at Stelinda Contractors
View Stelinda Contractors's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341526804.