Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PIONEER METAL FINISHING INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PIONEER METAL FINISHING INC. in 164 W 28TH AVE, OSHKOSH, WI 54902 (NAICS 332812). OSHA activity number 341532315.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pioneer Metal Finishing INC. — free Get an email when a new federal OSHA severe-injury report for Pioneer Metal Finishing INC. is published. One employer, no account, unsubscribe in one click.
Site address
164 W 28TH AVE
City
OSHKOSH
State
WI
ZIP
54902
Mailing
164 W 28TH AVE, OSHKOSH, WI 54902
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
55
Ownership type
A

20 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 30, 2016
Penalty
Initial $8,908 · Current $4,454 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:    a)  The employer did not ground the flammable storage cabinet containing a 55 gallon drum of Hydrite Chemical Co. RC LT High Actives. The 55 gallon drum of Hydrite Chemical Co. RC LT High Actives was grounded to the flammable storage cabinet and contents of the 55 gallon drum were dispensed into smaller containers for usage. Hydrite Chemical Co. RC LT High Actives is a category 2 flammable liquid. The flammable storage cabinet containing a 55 gallon drum of Hydrite Chemical Co. RC LT High Actives is located near the stand alone spray booths.
Recent events (2)
  • — I (S) $4454
  • — Z (S) $8908

1910.107 B05 I

Other-than-serious 1 instance 4 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $5,345 · Current $500 Reduced
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained. Filter rolls were not inspected to ensure proper replacement of filter media:    a) The manometers for the powder coating and paint standalone spray booths were not operational on June 9, 2016.    b) The exhaust duct filtering material was not correctly installed in the powder coating standalone spray booth on June 9, 2016. There were large gaps between the filtering material and the spray booth wall. The large gaps allowed the powder coating material to collect in the exhaust duct.
Recent events (2)
  • — I (O) $500
  • — Z (S) $5345

1910.124 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $8,908 · Current $4,454 Reduced
29 CFR 1910.124(g)(2): Employees who  worked with liquids that could burn, irritate, or otherwise harm their skin were not provided with an emergency shower and eye-wash station close to the dipping and coating operation:    a) The employer had not provided an emergency shower and eyewash station near the Alodine Line. The Alodine Replenisher, Cleaner and Rust Dissolver chemicals used on the Alodine Line can cause skin burns and irritation.
Recent events (2)
  • — I (S) $4454
  • — Z (S) $8908

1910.151 C

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) The eye wash bottles, near the Nitric Acid Dispensing Area in the aisle between the E-Coat Line and the Paint Line, are not capable of providing 15 minutes of flush.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.124 J01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $8,908 · Current $4,454 Reduced
29 CFR 1910.124(j)(1)(i): Hoods and ductwork of the ventilation system were not inspected for corrosion or damage at least quarterly during operation:    a) The hoods and ductwork of the Alodine Dip Line ventilation system was not inspected on a quarterly basis.
Recent events (2)
  • — I (S) $4454
  • — Z (S) $8908

1910.124 J02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.124(j)(2)(i): The employer did not ensure airflow was adequate at least quarterly during operation:  a) The airflow of the Alodine Dip Line ventilation systems was not inspected on a quarterly basis.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.124 J03

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.124(j)(3): Periodic inspections of all dipping and coating equipment, including covers, drains, overflow piping, and electrical and fire-extinguishing systems were not conducted, and deficiencies were not promptly corrected:  a) The employer's periodic inspections of the Alodine and Passivate Dip Lines did not include all of the interior and exterior tank surfaces, piping, drainage and structural components.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01 I

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $5,345 · Current $2,673 Reduced
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee from the hazards identified in the hazard assessment:    a) The Alodine/Passivation Line Operator did not wear face, hand or body protection while raising and lowering material in the Alodine Line dip tanks. Several Alodine Line dip tanks contain corrosive chemicals, such as nitric acid.
Recent events (2)
  • — I (S) $2672.5
  • — Z (S) $5345

1910.134 C01 VI

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $8,908 · Current $4,454 Reduced
29 CFR 1910.134(c)(1)(vi): The written program did not contain procedures to ensure adequate air quality, quantity, and flow of breathing air for atmosphere-supplying respirators:    a) The employer had not developed procedures to maintain the Blastmaster Respiratory Protector COC50 unit used to condition plant air into breathing air for the air supplied abrasive blasting helmet used in the abrasive blasting room.
Recent events (2)
  • — I (S) $4454
  • — Z (S) $8908

1910.134 F02

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  a) Employees required to wear half and full face cartridge respirators were not fit tested in 2015 or 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H04 II

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(4)(ii): Respirator repairs were not made in accordance with the manufacturer's recommendations and specifications for the type and extent of repairs to be performed:  a) Next to the abrasive blast room, the shroud for the abrasive blasting helmet was secured to the helmet with duct tape.  b) A Spray Painter on the Paint Line had masking tape over the exhalation valve cover on a full face cartridge respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 I05 III

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(i)(5)(iii): The compressor's sorbent bed and filters were not maintained and replaced or refurbished periodically as instructed by the manufacturer:  a) The abrasive blasting helmet air supply filtering system has not been serviced since 12/12/11.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 L01

Serious Gravity 5 1 instance 12 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(l)(1): Evaluations of the workplace were not conducted to ensure the written respiratory protection program was being effectively implemented:  a) The employer did not conduct evaluations of the respirator program. An evaluation of the respirator program requirements would have determine the medical evaluation provider was not conducting fit testing and the supplied air filtering system had not been serviced since 2011.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C04

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $5,345 · Current $2,673 Reduced
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:    a) Employees entering the 11 Stage Parts Washer, which is identified as a permit required confined space, are not complying with the employer's Confined Space Entry program requirements.
Recent events (2)
  • — I (S) $2672.5
  • — Z (S) $5345

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Nov 30, 2016
Penalty
Initial $8,908 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) The employer had not developed written energy control procedures for E-Coat and Waste Water PH Process equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8908

1910.147 C06 I

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  a) The employer had not conducted periodic inspections in 2015 or prior to June 8, 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 30, 2016
Penalty
Initial $5,345 · Current $2,673 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a) On June 6, 2016, the air nozzle used in Dry Off was operating at plant air pressure, which is above 90 PSI. The air nozzle was not designed to maintain a static pressure of less than 30 PSI if the nozzle opening became blocked.
Recent events (2)
  • — I (S) $2672.5
  • — Z (S) $5345

1910.305 G01 IV A

Deleted Serious Gravity 5 2 instances 7 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $7,126 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) The electrical source for the motors of the Shipping/Receiving dock plates were flexible cords.  b) An extension cord provided the electrical source for the R.O. Water Day Tank electrical components.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7126

1910.1200 E01 I

Other-than-serious 1 instance 45 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet:  a) The employer was not able to provide a list of hazardous chemicals present in the facility when requested on June 8, 2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F10

Other-than-serious 1 instance 20 exposed
Issued
Nov 30, 2016
Abate by
Dec 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warnings were legible, in English and prominently displayed on the container or readily available in the work area throughout each work shift:  a) The labels on Tanks 1 and 2 of the 11 Stage Washer were not legible on June 8, 2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Pioneer Metal Finishing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341532315.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.