PROVIDENCE, RI —
OSHA Inspection: MOULTON ENTERPRISES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MOULTON ENTERPRISES, INC. in 33 ACORN STREET, SUITE 105, PROVIDENCE, RI 02903 (NAICS 441310). OSHA activity number 341534626.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOULTON ENTERPRISES, INC.
- Site address
- 33 ACORN STREET, SUITE 105
- City
- PROVIDENCE
- State
- RI
- ZIP
- 02903
- Mailing
- 120 RALCO WAY, CUMBERLAND, RI 02864
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 1
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.22 A01
- Issued
- Jul 14, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: (a) Worksite: On or about 6/9/2016, the employer did not ensure that the workplace was kept in a clean and orderly condition, which created blocked aisles and tripping hazards throughout the storage area.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.176 A
- Issued
- Jul 14, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.176(a): Where mechanical handling equipment was used, sufficient safe clearances were not allowed for aisles, at loading docks, through doorways or wherever turns or passage had to be made: (a) Worksite: On or about 6/9/2016, the employer did not ensure that there was sufficient safe clearance to maneuver the forklift in the storage area.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.176 B
- Issued
- Jul 14, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: (a) Worksite: On or about 6/9/2016, the employer did not ensure that product was stored in a secure manner to avoid sliding or collapse.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Jul 14, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Worksite: On or about 6/9/2016, the employer did not ensure that the building and equipment main disconnects were clear of stored products.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.334 A01
- Issued
- Jul 14, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.334(a)(1): Flexible electric cords were fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation: (a) Worksite: On or about 6/9/2016, the employer allowed flexible electrical cords to be strung over and through pallet racking systems, as well as a fire suppression pumping unit and various hooks in the workplace.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.334 A02 I
- Issued
- Jul 14, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) Worksite: On or about 6/9/2016, the employer did not ensure that flexible power cords were inspected before use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Jul 14, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: (a) Worksite: On or about 6/9/2016, the employer did not ensure that a damaged extension cord used to power computer equipment in the shipping area was taken out of service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Moulton Enterprises, INC.
View Moulton Enterprises, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 441310)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341534626.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.