ARVADA, CO —
OSHA Inspection: BUENO'S ROOFING, REMODELING & EXTERIORS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BUENO'S ROOFING, REMODELING & EXTERIORS in 7431 WEBSTER ST., ARVADA, CO 80003 (NAICS 238160). OSHA activity number 341541977.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUENO'S ROOFING, REMODELING & EXTERIORS
- Site address
- 7431 WEBSTER ST.
- City
- ARVADA
- State
- CO
- ZIP
- 80003
- Mailing
- 10201 RIVERDALE RD LOT 49, THORNTON, CO 80229
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1053 B01
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. (a) On or about June 11, 2016, the employer did not ensure employees safely used the ladder to gain access to the residential roof. The ladder was not secured at the top and did not extend three feet above the landing surface. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.501 B13
- Issued
- Jul 12, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about June 11, 2016, the employees were exposed to injuries from falls approximately 18.0 feet while engaged in roofing activities. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections at Bueno'S Roofing, Remodeling & Exteriors
View Bueno'S Roofing, Remodeling & Exteriors's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341541977.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.