OSHA Inspection: THE BAR S U INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE BAR S U INC. in 17365 SOUTH COLE ROAD, KUNA, ID 83634 (NAICS 236220). OSHA activity number 341552826.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The BAR S U INC. — free Get an email when a new federal OSHA severe-injury report for The BAR S U INC. is published. One employer, no account, unsubscribe in one click.
Establishment
THE BAR S U INC.
Site address
17365 SOUTH COLE ROAD
City
KUNA
State
ID
ZIP
83634
Mailing
17168 NORTH FRONTAGE ROAD, FORT MORGAN, CO 80701
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
36
Ownership type
A

4 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 3 instances 4 exposed
Issued
Aug 22, 2016
Abate by
Aug 29, 2016
Penalty
Initial $8,730 · Current $5,000 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    (a) On or about June 13, 2016, and at times prior thereto, subcontractor employees were exposed to fall hazards greater than 8 feet while installing electrical equipment next to wall openings, where no guardrail was installed or other fall protection available or used.     (b) On or about June 13, 2016, and at times prior thereto, general contractor employees were exposed to fall hazards greater than 8 feet, while pumping water out of the basement sump pit, where no guardrail was installed or other fall protection available or used.     (c) On or about June 13, 2016, and at times prior thereto, a subcontractor employee was exposed to fall hazards greater than 17 feet, while standing at an exterior and unguarded wall opening, where no guardrail was installed or other fall protection available or used.     NOTE: Abatement certification and documentation is required for this item.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $8730

1926.1052 C01 I

Serious Gravity 1 2 instances 46 exposed
Issued
Aug 22, 2016
Penalty
Initial $3,742 · Current $1,871 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    (a) On or about June 13, 2016, and at times prior thereto, general contractor and subcontractor employees were exposed to fall and trip hazards when ascending and descending the stairs from the first floor to the basement, where no handrail was installed along the stairs.    (b) On or about June 13, 2016, and at times prior thereto, general contractor and subcontractor employees were exposed to fall and trip hazards when ascending and descending the first floor to the second floor mezzanine, where no handrail was installed along the stairs.      NOTE: Abatement certification is not required for this item.
Recent events (2)
  • — I (S) $1871
  • — Z (S) $3742

1926.34 B

Other-than-serious 4 instances 46 exposed
Issued
Aug 22, 2016
Abate by
Sep 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.34(b): Exits and access to exits were not marked by a readily visible sign:  (a) On or about June 13, 2016 and at times prior thereto exits and access to exits were not marked, where subcontractor employees were performing electrical, welding, pre-cast concrete erecting, and other portions of contractual work.  NOTE: Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.150 C01 I

Other-than-serious 1 instance 69 exposed
Issued
Aug 22, 2016
Abate by
Sep 16, 2016
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof and the travel distance from any point of the protected area to the nearest fire extinguisher exceeded 100 feet:    (a) On or about June 13 2016 and at times prior thereto, the required number of fire extinguishers were not provided in the 300,000 square foot building, where subcontractor employees were performing electrical, welding, pre-cast concrete and other portions of contractual work.    NOTE: Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $700

View The BAR S U INC.'s full OSHA safety record →