WASHINGTON, DC —
OSHA Inspection: SC CARPENTRY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SC CARPENTRY LLC in 4803 BUTTERWORTH PLACE NW, WASHINGTON, DC 20027 (NAICS 238130). OSHA activity number 341586907.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SC CARPENTRY LLC
- Site address
- 4803 BUTTERWORTH PLACE NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20027
- Mailing
- 1168 SOUTHERN NIGHT LN, GAITHERSBURG, MD 20879
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.403 B02
- Issued
- Nov 22, 2016
- Abate by
- Dec 1, 2016
- Penalty
- Initial $1,320 · Current $1,320
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about June 15, 2016 and at times prior thereto; second floor area; employees were plugged into an electrical box that was not installed permanently as it was intended. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1320
1926.501 B13
- Issued
- Nov 22, 2016
- Abate by
- Dec 1, 2016
- Penalty
- Initial $3,080 · Current $3,080
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about June 15, 2016; Second floor; employees working on framing the residential home were not protected from falling 10 foot fall to the lower level or 18 feet to ground level while working on the exposed working platform. b) On or about June 15, 2016; Second floor; first and second floor; employees working on framing a residential home were exposed to a 10 foot fall to the lower level while working near unguarded floor openings such as but not limited to the stair opening. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3080
1926.1053 B01
- Issued
- Nov 22, 2016
- Abate by
- Dec 1, 2016
- Penalty
- Initial $1,760 · Current $1,760
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed a) On or about June 15, 2016; first floor; employees were using an extension ladder that was flush to the working platform having the employees to reach for the ladder or platform; 10-foot fall. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1760
1926.405 G02 IV
- Issued
- Nov 22, 2016
- Abate by
- Dec 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws a) On or about June 15, 2016; Second floor; employee were operating a portable circular saw in which the conductors are no longer part of on the designed strain relief system of the equipment. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (O) $0
More inspections at SC Carpentry LLC
View SC Carpentry LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341586907.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.