CAMP DENNISON, OH —
OSHA Inspection: AIM MRO, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AIM MRO, LLC in 8500 GLENDALE MILFORD ROAD, CAMP DENNISON, OH 45111 (NAICS 332510). OSHA activity number 341587509.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIM MRO, LLC
- Site address
- 8500 GLENDALE MILFORD ROAD
- City
- CAMP DENNISON
- State
- OH
- ZIP
- 45111
- Mailing
- 8500 GLENDALE MILFORD ROAD, CAMP DENNISON, OH 45111
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332510
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Nov 18, 2016
- Abate by
- Dec 15, 2016
- Penalty
- Initial $8,730 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) There was no program on energy control procedures, employee training and periodic inspections, to include providing training to employees responsible for freeing up the furnace booster pump on the V1 Furnace.
Recent events (2)
- — I (O) $5000
- — Z (S) $8730
1910.147 D
- Issued
- Nov 18, 2016
- Abate by
- Dec 15, 2016
- Penalty
- Initial $8,730 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: (a) On or about June 21, 2016, an employee attempting to free up a furnace booster pump on the V1 Furnace, failed to first: (1) turn off and shut down the machine, (2) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (3) affix lockout or tagout devices to each energy isolating device.
Recent events (2)
- — I (S) $0
- — Z (S) $8730
More inspections at AIM MRO, LLC
View AIM MRO, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332510)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341587509.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.