Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIM MRO, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AIM MRO, LLC in 8500 GLENDALE MILFORD ROAD, CAMP DENNISON, OH 45111 (NAICS 332510). OSHA activity number 341587509.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIM MRO, LLC — free Get an email when a new federal OSHA severe-injury report for AIM MRO, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AIM MRO, LLC
Site address
8500 GLENDALE MILFORD ROAD
City
CAMP DENNISON
State
OH
ZIP
45111
Mailing
8500 GLENDALE MILFORD ROAD, CAMP DENNISON, OH 45111
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332510
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Other-than-serious 1 instance 5 exposed
Issued
Nov 18, 2016
Abate by
Dec 15, 2016
Penalty
Initial $8,730 · Current $5,000 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a)  There was no program on energy control procedures, employee training and periodic inspections, to include providing training to employees responsible for freeing up the furnace booster pump on the V1 Furnace.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $8730

1910.147 D

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 18, 2016
Abate by
Dec 15, 2016
Penalty
Initial $8,730 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:    (a)  On or about June 21, 2016, an employee attempting to free up a furnace booster pump on the V1 Furnace, failed to first:      (1)  turn off and shut down the machine,  (2)  physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source,  (3)  affix lockout or tagout devices to each energy isolating device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8730

View AIM MRO, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341587509.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.