HERRIN, IL —
OSHA Inspection: JOSEPH F. BECKER, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JOSEPH F. BECKER, INC. in 201 S 14TH ST, HERRIN, IL 62948 (NAICS 238140). OSHA activity number 341590941.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOSEPH F. BECKER, INC.
- Site address
- 201 S 14TH ST
- City
- HERRIN
- State
- IL
- ZIP
- 62948
- Mailing
- P.O. BOX 385, BREESE, IL 62230
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 F03
- Issued
- Dec 12, 2016
- Abate by
- Dec 16, 2016
- Penalty
- Initial $7,857 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about June 30, 2016, the Hydro Mobile M2 Series Scaffold, with a bridge span of 56 feet between the support towers, had a failure. Inspections of the scaffold components did not identify bearing bridge defects such but not limited to rust, the pitting of metal, and the failure to use manufacturer provided bearing bridge safety chains.
Recent events (2)
- — I (S) $0
- — Z (S) $7857
1926.451 F04
- Issued
- Dec 12, 2016
- Abate by
- Dec 16, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. On or about June 30, 2016, the Hydro Mobile M2 Series Scaffold bridge span (56 feet) was weakened such that the scaffold's strength was less than required and the section was not removed from service until repaired.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 B
- Issued
- Dec 12, 2016
- Abate by
- Dec 16, 2016
- Penalty
- Initial $5,612 · Current $4,209 Reduced
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work: The employer did not have each employee who was involved in inspecting the Hydro Mobile M2 Series scaffold trained to recognize collapse hazards, including the weakening effects of corrosion on the scaffold's support structure or the requirement to use the scaffold with safety chains in place.
Recent events (2)
- — I (S) $4209
- — Z (S) $5612
More inspections at Joseph F. Becker, INC.