OSHA Inspection: NOKOMIS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NOKOMIS, LLC in 62 STENNIS INDUSTRIAL PARK ROAD, DE KALB, MS 39328 (NAICS 332998). OSHA activity number 341592954.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nokomis, LLC for free Get an email when a new federal OSHA severe-injury report for Nokomis, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
NOKOMIS, LLC
Site address
62 STENNIS INDUSTRIAL PARK ROAD
City
DE KALB
State
MS
ZIP
39328
Mailing
62 STENNIS INDUSTRIAL PARK ROAD, DE KALB, MS 39328
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332998
Employees
29
Ownership type
Private (A)

5 citations on file for this inspection.

1910.212 A05

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 23, 2016
Abate by
Dec 16, 2016
Penalty
Initial $2,806 · Current $1,403 Reduced
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the fan's blades were not guarded by a guard which had openings no larger than one-half (1/2) inch.     (a) Finishing Area, west of Welding Enclosure - On or about June 30, 2016 employees were exposed to injury from fan blades due to a 5 11/16 inch diameter opening in the fan blade guard's center caused by the absence of, or due to, the missing emblem cover on the 30 inch diameter TPI Pedestal Fan, Model NSC 243, S/N 450408.
Recent events (2)
  • · I (S) $1403
  • · Z (S) $2806

1910.304 G05

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 23, 2016
Abate by
Dec 16, 2016
Penalty
Initial $2,806 · Current $1,403 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    (a) Finishing Area, west of Welding Enclosure - On or about June 30, 2016 employees were exposed to electric shock due to the following fan cord's grounding conductor having been severed/damaged, and a portion of the cord's outer insulation was missing, i.e., on the 30 inch diameter TPI Pedestal Fan, Model NSC 243, S/N 450408.
Recent events (2)
  • · I (S) $1403
  • · Z (S) $2806

1910.305 F02

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 23, 2016
Abate by
Dec 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(f): The conductor insulation was not approved for the voltage, operating temperature, and/or location of use:  (a) Finishing Area, west of Welding Enclosure - On or about June 30, 2016 employees were exposed to electric shock due to the following fan cord's outer insulation having been cut and/or missing for a length of approximately 4-6 inches, and the fan's grounding conductor, and its insulation, having been exposed and severed, i.e., on the 30 inch diameter TPI Pedestal Fan, Model NSC 243, S/N 450408.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.304 G06 VI C 5

Serious Gravity 1 2 instances 29 exposed
Issued
Nov 23, 2016
Abate by
Dec 16, 2016
Penalty
Initial $2,806 · Current $1,403 Reduced
29 CFR 1910.304(g)(6)(vi)(C)(5): Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment that could have become energized were not grounded under the following condition(s) listed in (C) of this paragraph, i.e., (5) cord- and plug-connected appliances used in damp or wet locations, or by employees standing on the ground or on metal floors or working inside of metal tanks or boilers:    (a) Near the southwest corner of the Wysong Shear - On or about June 30, 2016 employees were exposed to electrical shock due to the grounding prong missing from the fan's three-wire cord and plug, i.e., on the 30 inch diameter TPI Model NSC-243 Pedestal Fan, S/N 450335.
Recent events (2)
  • · I (S) $1403
  • · Z (S) $2806

1910.253 B04 III

Other-than-serious 1 instance 5 exposed
Issued
Nov 23, 2016
Abate by
Dec 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  (a) West wall, between the Roll-up Doors - On or about June 30, 2016 employees were exposed to minor injury due to one small capped acetylene cylinder being stored in the same storage rack beside one small capped oxygen cylinder and an empty Argon cylinder.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Nokomis, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341592954.