Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OCHOA ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OCHOA ROOFING in BLDG 8161 & 8191 BACK BAY CT., DAYTON, OH 45458 (NAICS 238160). OSHA activity number 341595395.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ochoa Roofing — free Get an email when a new federal OSHA severe-injury report for Ochoa Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
OCHOA ROOFING
Site address
BLDG 8161 & 8191 BACK BAY CT.
City
DAYTON
State
OH
ZIP
45458
Mailing
1328 WEST JEFFERSON STREET, KOKOMO, IN 46901
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 28, 2016
Penalty
Initial $2,800 · Current $1,000 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    Located throughout a residential roof structure, employees were observed removing roofing shingles on a low pitch roof while not utilizing an adequate fall protection system. Potential fall heights were measured to be greater than 25' with a roof pitch of 4 in12.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2800

1926.503 B01

Serious Gravity 1 1 instance 10 exposed
Issued
Jul 28, 2016
Abate by
Aug 16, 2016
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.    Employer did not have written certification record to verify employees had been adequately trained in fall protection that contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. Employees were exposed to a fall height greater than 25' while removing shingles on a low pitch residential roof.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1200

View Ochoa Roofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341595395.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.