ATHENS, GA —
OSHA Inspection: PILGRIM'S CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PILGRIM'S CORPORATION in 898 BARBER ST, ATHENS, GA 30606 (NAICS 311615). OSHA activity number 341598514.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PILGRIM'S CORPORATION
- Site address
- 898 BARBER ST
- City
- ATHENS
- State
- GA
- ZIP
- 30606
- Mailing
- 898 BARBER ST, ATHENS, GA 30606
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311615
- Employees
- 1590
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.22 C
- Issued
- Dec 15, 2016
- Abate by
- Sep 28, 2017
- Penalty
- Initial $5,880 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc. On 6/29/16, at the Athens facility in the Picking Room, employees were exposed to trip hazards as portions of the drainage pits at Lines 1 and 2 in the picking room were left uncovered.
Recent events (3)
- — F (O) $4000
- — C (S) $5880
- — Z (S) $5880
1910.147 C04 I
- Issued
- Dec 15, 2016
- Abate by
- Jan 12, 2017
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. On 6/15/16, at the Athens facility, employees were not utilizing Lockout procedures for various service and maintenance activities on site including: a - On 6/15/16 a sanitation employee received an amputation while attempting to remove paws from a moving shackle line. b - Sanitation employees did not utilize the documented LOTO procedure for locking out shackle lines for service and maintenance activities.
Recent events (3)
- — F (S) $0
- — C (S) $12471
- — Z (S) $12471
1910.147 C04 II
- Issued
- Dec 15, 2016
- Abate by
- Feb 3, 2017
- Penalty
- Initial $9,799 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy. On 7/19/16, at the Athens facility, the Lockout/Tagout procedures implemented at the facility were not in a language all Authorized employees could understand. i.e. Spanish speaking/reading employees had Lockout procedures provided in English only.
Recent events (3)
- — F (S) $0
- — C (S) $9799
- — Z (S) $9799
1910.147 C06 I
- Issued
- Dec 15, 2016
- Abate by
- Nov 28, 2017
- Penalty
- Initial $12,471 · Current $12,471
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. On 6/15/16, at the Athens facility, the employer has not performed a periodic inspection of the established Lockout/Tagout program to ensure procedures were established and correct.
Recent events (3)
- — F (O) $12471
- — C (S) $12471
- — Z (S) $12471
1910.147 D04 I
- Issued
- Dec 15, 2016
- Abate by
- Feb 3, 2017
- Penalty
- Initial $9,799 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. On 7/19/16, at the Athens facility, managers were applying lockout devices for sanitation employees performing cleaning activities of the Picking Lines.
Recent events (3)
- — F (S) $0
- — C (S) $9799
- — Z (S) $9799
1910.212 A01
- Issued
- Dec 15, 2016
- Abate by
- Sep 28, 2017
- Penalty
- Initial $12,471 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points, rotating parts, and flying chips. On 11/2/16, in the Picking Room at the Athens facility, the employer did not ensure machine guarding provided was effective at the following machines: (a) On or about 6/15/16, in the Picking Room at the Athens facility, employees manually removing paws from shackles left from the automated removal process were exposed to the hazard of being caught in a shackle without adequate means to stop the shackle line. (b) On 11/2/16, Lines 1 and 2 in the Picking Room at the Athens facility, the doors of the auto rehanger machines, equipped by the manufacturer, were observed left in an open position.
Recent events (3)
- — F (S) $8000
- — C (S) $12471
- — Z (S) $12471
1910.212 A05
- Issued
- Dec 15, 2016
- Abate by
- Sep 28, 2017
- Penalty
- Initial $12,471 · Current $12,471
General-duty citation text
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch. On 11/2/16, in the Picking Room of the Athens facility, the employer did not guard the ventilation fan blades adequately on a fan that was within 3 feet of the floor. Louvers on the fan were 4 1/2 inches wide and when open did not guard the rotating blades.
Recent events (3)
- — F (O) $12471
- — C (S) $12471
- — Z (S) $12471
1910.219 C02 I
- Issued
- Dec 15, 2016
- Abate by
- Sep 28, 2017
- Penalty
- Initial $12,471 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting. On 11/2/16, in the Picking Room area at the Athens facility, the employer did not ensure motor shafts on the Hock Cutting machine were guarded. Shafts are located 55 inches from floor levels.
Recent events (3)
- — F (O) $5000
- — C (S) $12471
- — Z (S) $12471
1910.303 B02
- Issued
- Dec 15, 2016
- Abate by
- Sep 28, 2017
- Penalty
- Initial $9,799 · Current $12,471
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. On 7/19/16, at the Athens facility in the Power Picking Room, the employer did not install electrical equipment that was listed/labeled for that purpose. i.e. the employer had used a clear Plexiglas front as a cover for a 480v. electrical panel.
Recent events (3)
- — F (S) $12471
- — C (S) $9799
- — Z (S) $9799
1910.303 G02 I
- Issued
- Dec 15, 2016
- Abate by
- Jan 12, 2017
- Penalty
- Initial $12,471 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). On 7/19/16, in the Picking Power Room at the Athens facility, employees were exposed to 480 volt electrical hazards as employees, both sanitation and maintenance, routinely accessed electrical panels to turn breakers off for other equipment within the panel that was to be serviced and maintained.
Recent events (3)
- — F (S) $0
- — C (S) $12471
- — Z (S) $12471
1910.335 A01 II
- Issued
- Dec 15, 2016
- Abate by
- Sep 28, 2017
- Penalty
- Initial $9,799 · Current $7,500 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested. On 7/19/2016, at the Athens facility, the employer did not have arc flash personal protective gloves inspected. Gloves were purchased in June of 2015 but have not been inspected since their initial purchase.
Recent events (3)
- — F (O) $7500
- — C (S) $9799
- — Z (S) $9799
1910.134 D01 II
- Issued
- Dec 15, 2016
- Abate by
- Jan 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification. On 11/2/16, in the Picking Room of the Athens facility, employees were permitted to use single strap dust mask respirators that were not NIOSH approved.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Pilgrim'S Corporation
View Pilgrim'S Corporation's full OSHA safety record →
More inspections in this industry (NAICS 311615)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341598514.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.