Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ANALYTICAL SERVICES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ANALYTICAL SERVICES, INC. in 51 PRO CHEM TECH DRIVE, BROCKWAY, PA 15824 (NAICS 541380). OSHA activity number 341601672.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Analytical Services, INC. for free Get an email when a new federal OSHA severe-injury report for Analytical Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
51 PRO CHEM TECH DRIVE
City
BROCKWAY
State
PA
ZIP
15824
Mailing
51 PRO CHEM TECH DRIVE, BROCKWAY, PA 15824
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541380
Employees
15
Ownership type
A

5 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 29, 2016
Abate by
Sep 15, 2016
Penalty
Initial $2,000 · Current $1,300 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:       a.) Analytical Services, Inc. 51 Pro Chem Tech Dr., Brockway, PA, 15824-Lab hood area- on or about July 6th, 2016 and times prior thereto:  Employees worked with and around corrosive materials including, but not limited to, Hydrochloric Acid, and Nitric Acid during laboratory analysis of samples.  Suitable facilities for quick drenching and flushing of the eyes and/or body were not available in the area where corrosive liquids were used.
Recent events (2)
  • · I (S) $1300
  • · Z (S) $2000

1910.1450 E01

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 29, 2016
Abate by
Sep 15, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.1450(e)(1): Where hazardous chemicals were used in the workplace, the employer did not develop and carry out the provisions of a written Chemical Hygiene Plan which was capable of protecting employees from health hazards associated with hazardous chemicals:       a.) Analytical Services, Inc. 51 Pro Chem Tech Dr., Brockway, PA, 15824-Lab hood area- on or about July 6th, 2016 and times prior thereto:  Employees worked with and around hazardous chemicals including, but not limited to, Hydrochloric Acid, and Nitric Acid during laboratory analysis of samples.  The employer did not develop and maintain a Chemical Hygiene Plan.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.1450 F01

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 29, 2016
Abate by
Sep 15, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.1450(f)(1): The employer did not provide laboratory employees with information and training to ensure that they were apprised of the hazards of chemicals present in their work area:         a.) Analytical Services, Inc. 51 Pro Chem Tech Dr., Brockway, PA, 15824-Lab hood area- on or about July 6th, 2016 and times prior thereto:  Employees worked with and around hazardous chemicals including, but not limited to, Hydrochloric Acid, and Nitric Acid during laboratory analysis of samples.  Employees were not provided with training related to the hazardous chemicals in and around their work areas.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.1450 F04 I B

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 29, 2016
Abate by
Sep 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1450(f)(4)(i)(B): Employee training did not include the physical and health hazards of the chemicals in the work area:     a.) Analytical Services, Inc. 51 Pro Chem Tech Dr., Brockway, PA, 15824-Lab hood area- on or about July 6th, 2016 and times prior thereto:  Employees worked with and around hazardous chemicals including, but not limited to, Hydrochloric Acid, and Nitric Acid during laboratory analysis of samples.  Employees were not provided with training related to physical and health hazards of chemicals in the laboratory.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1450 F04 II

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 29, 2016
Abate by
Sep 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1450(f)(4)(ii): The laboratory employee was not trained on the applicable details of the employer's written Chemical Hygiene Plan:     a.) Analytical Services, Inc. 51 Pro Chem Tech Dr., Brockway, PA, 15824-Lab hood area- on or about July 6th, 2016 and times prior thereto:  Employees worked with and around hazardous chemicals including, but not limited to, Hydrochloric Acid, and Nitric Acid during laboratory analysis of samples.  Employees were not trained on the contents of the employers written Chemical Hygiene Plan in that, the employer did not maintain a Chemical Hygiene plan.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Analytical Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341601672.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.