EL PASO, TX —
OSHA Inspection: TEXAS PLUMBING CONTRACTORS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TEXAS PLUMBING CONTRACTORS, LLC in 3801 CONSTITUTION DR., EL PASO, TX 79922 (NAICS 238220). OSHA activity number 341634111.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEXAS PLUMBING CONTRACTORS, LLC
- Site address
- 3801 CONSTITUTION DR.
- City
- EL PASO
- State
- TX
- ZIP
- 79922
- Mailing
- 6963 COMMERCE AVE., EL PASO, TX 79915
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 35
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.21 B02
- Issued
- Jan 10, 2017
- Abate by
- Feb 10, 2017
- Penalty
- Initial $11,224 · Current $7,333 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: Excavation Site: On or about July 20, 2016, employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to trenching and excavation. Employees were working in a trench greater than 5-feet without any cave-in protection. This condition exposed employees to struck-by and cave-in hazards.
Recent events (2)
- — I (S) $7333.35
- — Z (S) $11224
1926.651 C02
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $11,224 · Current $7,333 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: Excavation Site: On or about July 20, 2016, the employer did not provide a safe means to egress within 25-feet of lateral travel for employees working in an excavation that was approximately 172-feet 8-inches in length and 5 to 6-feet deep. This condition exposed employees to cave-in hazards.
Recent events (2)
- — I (S) $7333.33
- — Z (S) $11224
1926.651 J02
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $11,224 · Current $7,333 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of the excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. Excavation Site: On or about July 20, 2016, the excavated material was not kept at least 2 feet from the edge of the excavation. This condition exposed employees to struck-by and cave-in hazards.
Recent events (2)
- — I (S) $7333.33
- — Z (S) $11224
1926.651 K01
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $11,224 · Current $7,333 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. Excavation Site: On or about July 20, 2016, daily inspections were not conducted by the competent person (as designated by the employer) prior to the start of work and as needed throughout the shift(s). This condition exposed employees to cave-in hazards.
Recent events (2)
- — I (S) $7333.33
- — Z (S) $11224
1926.651 K02
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(2): Where there was evidence of a situation that could result in a possible cave-in or other hazardous condition the competent person did not remove exposed employees until necessary precautions could be taken to ensure their safety. Excavation Site: On or about July 20, 2016, the Competent Person (as designated by the employer) did not take any precautions where there was evidence of a situation that could result in a possible cave-in or other hazardous condition. The soil was previously disturbed (twice) and very sandy. This condition exposed employees to cave-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $11,224 · Current $7,333 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c): Excavation Site: On or about July 20, 2016, the employer did not provide an adequate protective system for employees working in the excavation that was approximately 172-feet 8-inches in length and 5 to 6-feet deep. This condition exposed employees to cave-in hazards.
Recent events (2)
- — I (S) $7333.33
- — Z (S) $11224
1926.652 B02
- Issued
- Jan 10, 2017
- Abate by
- Jan 23, 2017
- Penalty
- Initial $11,224 · Current $7,333 Reduced
General-duty citation text
29 CFR 1926.652(b)(2): Maximum allowable slopes, and allowable configurations for sloping and benching systems, was not determined in accordance with the conditions and requirements set forth in Appendices A and B to this subpart. Excavation Site: On or about July 20, 2016, the employer or his designee did not conduct soil classification tests in order to determine the maximum allowable slopes, and allowable configurations for sloping and benching systems in accordance Appendices A and B to this subpart. This condition exposed employees to cave-in hazards.
Recent events (2)
- — I (S) $7333.33
- — Z (S) $11224
More inspections at Texas Plumbing Contractors, LLC
View Texas Plumbing Contractors, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341634111.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.