BRONX, NY —
OSHA Inspection: MICON GROUP NY, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MICON GROUP NY, LLC in 1417 LONGFELLOW AVE., BRONX, NY 10459 (NAICS 238140). OSHA activity number 341655959.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MICON GROUP NY, LLC
- Site address
- 1417 LONGFELLOW AVE.
- City
- BRONX
- State
- NY
- ZIP
- 10459
- Mailing
- 110 SCHENCK BLVD., FLORAL PARK, NY 11001
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 17
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.404 B01 I
- Issued
- Aug 1, 2016
- Abate by
- Aug 9, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: Location: 4th floor On or about: 5/31/16 a) An employee was using electrical equipment, including a circular saw, while engaged in carpentry work. The employee was not provided with GFCI protection or an assured equipment grounding conductor program. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2000
1926.404 F06
- Issued
- Aug 1, 2016
- Abate by
- Aug 9, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Location: 4th floor On or about: 5/31/16 a) An employee was using a circular saw plugged into an electrical extension cord, while engaged in carpentry work. The electrical cord had an open ground. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $0
1926.501 B01
- Issued
- Aug 1, 2016
- Abate by
- Aug 9, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 5th floor On or about: 5/31/16 a) Employees were engaged in masonry work, 37.5 feet above the ground and 9 feet 4 inches above the lower level. The employees were not protected from falling to the ground and floor below. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2800
1926.501 B14
- Issued
- Aug 1, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. Location: 4th floor On or about: 5/31/16 a) Employees were engaged in masonry work, 28 feet above the ground. The employees were not protected from falling to the ground below. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2000
1926.701 B
- Issued
- Aug 1, 2016
- Abate by
- Aug 9, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, was not guarded to eliminate the hazard of impalement: location: 5th floor on or about: 5/31/16 a) Employees were working beside unguarded rebar. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1200
1926.1052 B01
- Issued
- Aug 1, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan: Location: stairs between 4th and 5th floors On or about: 5/31/16 a) Employees used the stairs for access between the 4th and 5th floors. The treads of the pan stairs were not adequately filled in. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1200
1926.1052 C01 I
- Issued
- Aug 1, 2016
- Abate by
- Aug 9, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: Location: stairs between 4th and 5th floors On or about: 5/31/16 a) Employees used the stairs for access between the 4th and 5th floors. The closed stairs did not have a handrail. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $1200
More inspections at Micon Group NY, LLC
View Micon Group NY, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341655959.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.