Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CISCO LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CISCO LLC in 740 JAMES STREET, NEW HAVEN, CT 06519 (NAICS 237990). OSHA activity number 341670321.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cisco LLC — free Get an email when a new federal OSHA severe-injury report for Cisco LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CISCO LLC
Site address
740 JAMES STREET
City
NEW HAVEN
State
CT
ZIP
06519
Mailing
525 ELLA GRASSO BOULEVARD, NEW HAVEN, CT 06519
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Other-than-serious 1 instance 2 exposed
Issued
Nov 25, 2016
Abate by
Dec 5, 2016
Penalty
Initial $4,988 · Current $4,988
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s)    WORKSITE: The employer did not ensure that a competent person conducted frequent and regular inspections of the worksite, materials and equipment prior to employees torch cutting and removing pipes that had not been properly disconnected from the roof trusses.       On or about July 19, 2016, while employees were pulling trusses from the building, a fire sprinkler pipe that was not completely separated from the trusses struck a scissors lift. The scissors lift was knocked over causing an employee to sustained serious injuries from the incident.
Recent events (2)
  • — I (O) $4988
  • — Z (S) $4988

1926.850 A

Other-than-serious 1 instance 2 exposed
Issued
Nov 25, 2016
Abate by
Dec 5, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.850(a): Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations:(a)(IDENTIFY LOCATION(S))    WORKSITE: The employer did not provide written evidence that an engineering survey was performed by a competent person prior to employees commencing manual demolition operations.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.350 A09

Other-than-serious 2 instances 2 exposed
Issued
Nov 25, 2016
Abate by
Dec 5, 2016
Penalty
Initial $3,563 · Current $3,563
29 CFR 1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times:    WORKSITE: The free-standing oxygen and acetylene tanks in the following locations were subject to damage from vehicular traffics and equipment moving with in very close proximity, and they were not secured to prevent accidental displacement:       A.     Corner of the building next to a fuel tank and parking area in front of the garage door.  B.     Next to the wall on the opposite end of the fuel tank.
Recent events (2)
  • — I (O) $3563
  • — Z (S) $3563

View Cisco LLC's full OSHA safety record →