Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CISCO, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CISCO, LLC in 801 BRIDGEPORT AVENUE, SHELTON, CT 06484 (NAICS 238910). OSHA activity number 341827582.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cisco, LLC — free Get an email when a new federal OSHA severe-injury report for Cisco, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CISCO, LLC
Site address
801 BRIDGEPORT AVENUE
City
SHELTON
State
CT
ZIP
06484
Mailing
525 ELLA GRASSO BOULEVARD, NEW HAVEN, CT 06519
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
28
Ownership type
A

2 citations on file for this inspection.

1926.651 K01

Other-than-serious 1 instance 2 exposed
Issued
Jan 13, 2017
Abate by
Jan 20, 2017
Penalty
Initial $7,482 · Current $0 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems.    Jobsite:  The employer did not ensure that the excavation, the adjacent areas, and the protective system were inspected by a competent person prior to allowing the employees to enter into the excavation/trench.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7482

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 13, 2017
Abate by
Jan 20, 2017
Penalty
Initial $8,730 · Current $8,000 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).     Jobsite: The employees, working in an excavation that ranged in depth up to 16 feet deep were not protected from cave-ins by the use of appropriate cave-in protection system/devices.    On or about 10/10/2016, a side wall of the excavation/trench caved in, and an employee sustained multiple broken bones injuries from the incident.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $8730

View Cisco, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341827582.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.