Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERIPRIDE SERVICES INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERIPRIDE SERVICES INC. in 105 LANDRUM ST., DURANT, MS 39063 (NAICS 812331). OSHA activity number 341680049.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ameripride Services INC. — free Get an email when a new federal OSHA severe-injury report for Ameripride Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
105 LANDRUM ST.
City
DURANT
State
MS
ZIP
39063
Mailing
105 LANDRUM ST., DURANT, MS 39063
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812331
Employees
74
Ownership type
A

3 citations on file for this inspection.

1910.303 C01 I

Serious Gravity 1 1 instance 20 exposed
Issued
Aug 11, 2016
Abate by
Aug 15, 2016
Penalty
Initial $2,863 · Current $1,718 Reduced
29 CFR 1910.303(c)(1)(i): Devices such as pressure terminal or pressure splicing connectors and soldering lugs shall be identified for the material of the conductor and shall be properly installed and used;  (a) Flat Work - On or about July 19, 2016 metal conduit pipe supplying power to outlet has separated at splicing connector exposing live electrical wires inside to sharp edges.
Recent events (2)
  • — I (S) $1717.8
  • — Z (S) $2863

1910.305 G01 IV

Serious Gravity 5 1 instance 74 exposed
Issued
Aug 11, 2016
Abate by
Aug 19, 2016
Penalty
Initial $3,816 · Current $2,290 Reduced
29 CFR 1910.305(g)(1)(iv): Extension cords and/or power strips were being used in lieu of permanent building wiring.  (a) Machine Room - On or about July 19, 2016 employer was using an extension cord with a power strip plugged into it to supply power the four water tanks that is over forty feet away.
Recent events (2)
  • — I (S) $2289.6
  • — Z (S) $3816

1910.37 B06

Other-than-serious 1 instance 74 exposed
Issued
Aug 11, 2016
Abate by
Aug 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  (a) Exit Door Next to Receiving - On or about July 19, 2016 the exit sign above the exit door was not illuminated. Battery was drained of power and hanging outside the unit.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Ameripride Services INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341680049.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.