Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREAT ELECTRIC GROUP, LLC

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of GREAT ELECTRIC GROUP, LLC in 960 BROADWAY, ALBANY, NY 12207 (NAICS 238210). OSHA activity number 341686756.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Great Electric Group, LLC — free Get an email when a new federal OSHA severe-injury report for Great Electric Group, LLC is published. One employer, no account, unsubscribe in one click.
Site address
960 BROADWAY
City
ALBANY
State
NY
ZIP
12207
Mailing
687 EASTLINE RD., BALLSTON SPA, NY 12020
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.62 D01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 15, 2016
Abate by
Jan 4, 2017
Penalty
Initial $3,741 · Current $2,430 Reduced
29 CFR 1926.62(d)(1)(i): Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level of 30 micrograms per cubic meter of air calculated as an 8-hour time-weighted average (TWA):                a) On or about 6/15/2016 through 7/13/2016, throughout 960 Broadway building, electricians were exposed to lead while working in and around a workplace where employees were performing demolition and carpentry activities in an area where lead was present in debris on the floor and in paint on the walls, ceilings, columns, and surfaces.  The employer did not conduct initial assessment of employees exposures to lead.
Recent events (2)
  • — I (S) $2430
  • — Z (S) $3741

1926.62 L01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 15, 2016
Abate by
Jan 4, 2017
Penalty
Initial $3,741 · Current $2,430 Reduced
29 CFR 1926.62(l)(1)(i): The employer did not include lead in the program established to comply with the Hazard Communication Standard (HCS) (� 1910.1200):     a) On or about 6/15/2016 through 7/13/2016, throughout 960 Broadway building, electricians were exposed to lead while working in and around a workplace where employees were performing demolition and carpentry activities in an area where lead was present in debris on the floor and in paint on the walls, ceilings, columns, and surfaces.  The employer did not include information on the reproductive hazards and the effects on central nervous system, kidney, blood, and acute toxicity.
Recent events (2)
  • — I (S) $2430
  • — Z (S) $3741

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 15, 2016
Abate by
Dec 27, 2016
Penalty
Initial $3,741 · Current $2,430 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:      a) On or about 6/15/2016 through 7/13/2016, 960 Broadway building second, third, and fourth floors, the electricians who were installing electrical panels, outlets, temporary lighting, and wiring were required to walk through areas where large sections of floors had been removed. No fall protection systems were utilized and/or no guardrails or safety nets were installed in these areas, thereby exposing the employees to a fall hazard over 12 feet.
Recent events (2)
  • — I (S) $2430
  • — Z (S) $3741

1926.501 B04 II

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 15, 2016
Abate by
Dec 27, 2016
Penalty
Initial $3,741 · Current $0 Reduced
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers:     a) On or about 6/15/2016 through 7/13/2016, throughout 960 Broadway building, for the electricians who were installing electrical panels, outlets, temporary lighting, and wiring were required to work in and walk through areas where there were floor holes measuring up to 4 feet by 4 feet which were not covered on the second, third, and fourth floors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3741

View Great Electric Group, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341686756.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.