FLAGLER, CO —
OSHA Inspection: WAGNER'S LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WAGNER'S LLC in 101 E 4TH ST, FLAGLER, CO 80815 (NAICS 424510). OSHA activity number 341699320.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAGNER'S LLC
- Site address
- 101 E 4TH ST
- City
- FLAGLER
- State
- CO
- ZIP
- 80815
- Mailing
- 2812 E. 1100 N. RD, MILFORD, IL
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 90
- Ownership type
- A
Citations
17 citations on file for this inspection.
1910.24 H
- Issued
- Oct 17, 2016
- Abate by
- Dec 5, 2016
- Penalty
- Initial $4,988 · Current $4,988
General-duty citation text
29 CFR 1910.24(h): Standard Railings were not provided on the open sides of all exposed stairways and stair platforms: a) North Production Plant, Mezzanine Level: On or about August 10, 2016, and at times prior, a worker on the stair landing was exposed to falling from a height of approximately 10 feet. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $4988
- — Z (S) $4988
1910.23 D01 II
- Issued
- Oct 17, 2016
- Abate by
- Nov 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1)(ii): Stairways less than 44 inches wide having one side open, did not have at least one stair railing on the open side: b) North Production Plant: On or about August 10, 2016, and at times prior, workers were exposed trip and fall hazards due to a missing midrail on the standard stair railing, left side ascending, located on the main stairway to the mezzanine level approximately 10 feet high. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.23 D01 III
- Issued
- Oct 17, 2016
- Abate by
- Dec 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side: a) North Production Plant, Loading Dock: On or about August 10, 2016, and at times prior, workers were exposed to trip and fall hazards due to missing midrails and standard railings at the stairs on the north and south sides of the loading dock. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A02
- Issued
- Oct 17, 2016
- Abate by
- Nov 10, 2016
- Penalty
- Initial $4,988 · Current $4,988
General-duty citation text
29 CFR 1910.22(a)(2): The floor of every workroom was no maintained in a clean, and so far as possible, a dry condition: a) East Elevator: On or about August 10, 2016, and at times prior, workers were exposed to hazards from accumulated waste products. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $4988
- — Z (S) $4988
1910.141 A05
- Issued
- Oct 17, 2016
- Abate by
- Nov 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(a)(5): A continuing and effective extermination program was not instituted where rodents, insects, or other vermin were detected: a) East Elevator: On or about August 10, 2016, and at times prior, workers were exposed to various hazards where birds such as pigeons were not prevented from entering, inhabiting, or exterminated from the facility. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A05
- Issued
- Oct 17, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $3,741 · Current $1,924 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a) North Production Plant, Mezzanine Level: On or about August 10, 2016, and at times prior, a worker was exposed to possible hazard due to an unguarded fan. Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $1924
- — Z (S) $3741
1910.219 C04 I
- Issued
- Oct 17, 2016
- Abate by
- Nov 10, 2016
- Penalty
- Initial $6,236 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) South Production Plant, Second Floor: On or about August 10, 2016, and at times prior, workers were exposed to potential for injury due to an unguarded auger drive gear shaft. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $6236
1910.23 A09
- Issued
- Oct 17, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(9): Every floor hole into which persons cannot accidentally walk (on account of fixed machinery, equipment or walls) was not protected by a cover that leaves no openings more than 1 inch wide. The cover shall be securly held in palce to prevent tools or materials from falling through: a) Cleaner Mill: On or about August 10, 2016, and at times prior, workers were exposed trip and fall hazards where clean grain was gravity fed into the storage bin through a floor hole that was not adequately guarded. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.36 E01
- Issued
- Oct 17, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(e)(1): A side-hinged door was not used to connect any room to an exit route: a) North Production Plant: On or about August 10, 2016, and at times prior, workers were exposed to fire hazard due to a vertically opening bay door being designated for use as an emergency exit. Doors of this type are an improper means of egress during an emergency. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B07
- Issued
- Oct 17, 2016
- Abate by
- Nov 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(7): Each exit sign did not have the word "Exit" in plainly eligible letters not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three fourths of an inch (1.9 cm) wide: a) North Production Plant: Signs denoting emergency egress doors did not meet lettering requirements. b) North Production Plant: On or about August 10, 2016, and at times prior, workers were exposed to fire hazard due to a vertically opening bay door being designated for use as an emergency exit. Doors of this type are an improper means of egress during an emergency. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 K01
- Issued
- Oct 17, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(k)(1): The wheel chocks were not placed under the rear wheels of highway trucks to prevent the trucks from rolling while they were boarded with powered industrial trucks: a) North Production Plant: On or about August 10, 2016, and at times prior, workers were exposed to potential for injury due to available wheel chocks not being used while a powered industrial truck was on board. Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.138 B
- Issued
- Oct 17, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(b): The employer did not base the selection of the appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the task(s) being performed, conditions present, duration of use, and the hazards and potential hazards identified: a) Mill Cleaner: On or about August 10, 2016, and at times prior, workers were exposed to chemical hazards while mixing the pesticide Diacon. Workers were not wearing appropriate personal protective equipment to protect them from dermal exposure (rubber gloves). Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.133 A01
- Issued
- Oct 17, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Mill Cleaner: On or about August 10, 2016, and at times prior, workers were exposed to chemical hazards while mixing the pesticide Diacon. Workers were not wearing appropriate personal protective equipment to protect them from splash hazards (chemical goggles). Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 G05
- Issued
- Oct 17, 2016
- Abate by
- Nov 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) South Production Plant, Second Floor: On or about August 10, 2016, and at times prior, workers were exposed to electrical hazards where the path to ground was broken in the globe area due to a broken fitting. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 J01
- Issued
- Oct 17, 2016
- Abate by
- Nov 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(1): Fixtures, lampholders, lamps, rosettes, and receptacles had live parts normally exposed to employee contact: a) South Production Plant, Second Floor: On or about August 10, 2016, and at times prior, workers were exposed to electrical hazards due to an exposed bulb without a protective cage five feet above the platform level. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B01 VIII
- Issued
- Oct 17, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1)(viii): Electrical equipment was not free from recognized hazards based on other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment: a) Mill Cleaner, Office Building: On or about August 10, 2016, and at times prior, workers were exposed to electrical hazards due to damaged outer protective cover of insulated wires on the power cord of the Ferrell-Ross Clipper office tester. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G11
- Issued
- Oct 17, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(11): Safety data sheets were not made readily available upon request, to designated representatives, the Assistant Secretary, and the Director, in accordance with the requirements of 1910.1200: a) On or about August 10, 2016, and at times prior, Safety Data Sheets were not provided in a timely manner to compliance officers upon request. These were locked in the managers office who was not present. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Wagner'S LLC
View Wagner'S LLC's full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341699320.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.